Suggestions

Flow Meter DULCOFLOW

For the measurement of pulsating volumetric flows within the range of 0.03 ml/stroke to 10 ml/stroke

The flow meter DULCOFLOW reliably measures pulsating flows in the range above 0.03 ml/stroke based on the ultrasound measuring principle. The flow meter achieves maximum chemical resistance as all wetted parts are made of PVDF and PTFE.

Product description

Your reliable control unit: unobtrusively measures, monitors and detects faults.

The device works on the ultrasound measuring principle. It was developed specifically for measuring small pulsating volumetric flows. It is installed around 30 cm downstream of the metering pump, so that there is still sufficient pulsation in the flow. All liquids that conduct ultrasound waves can be measured.

Your benefits

  • Maximum chemical resistance by the use of PVDF and PTFE
  • No electrical conductivity of the medium is needed
  • Measurement above stroke volumes of approx. 30 µl
  • Detection of gas bubbles in the feed chemical
  • No bottlenecks in the measuring tube. Media with small undissolved particles or with increased viscosity can be measured
  • A 0/4 -20 mA current output and a frequency output are available for remote transmission of the measured values.
  • The use of cookies is required to play this video. Here you can adjust your cookie selection to watch this video.

    ProMinent Flow Meter DULCOFLOW

Field of application

The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.

  • Measurement of the chemical consumption, for example in surface treatment.
  • Guaranteed metering, for example in the paper industry.
  • Measured value transmission and pump control by the central control system.
  • Measurement of aggressive chemicals.
  • Not suitable for liquids, which have minimal acoustic conductivity, e.g. sodium hydroxide (NaOH) with a concentration of greater than around approx. 20%.
  • We recommend first testing the measurability with emulsions and suspensions.
  • Media like chlorine dioxide liquids, which can penetrate through PVDF, can lead to shorter lifetime of the transducers.

    Technical Details

    • 2 LEDs for status display and stroke feedback
    • 2-line graphic display
    • 0/4-20 mA standard signal and 0 – 10 kHz frequency output for remote transmission of the measured value
    • Compact, chemically-resistant plastic housing
    • Measuring accuracy ± 2 % if the device has been calibrated to the chemical to be measured. Max. operating pressure 16 bar.

    Technical Data

    Type 05

    Type 08

    Max. operating pressure

    16 bar

    16 bar

    Smallest measurable stroke volume

    Approx. 0.03 ml/stroke, pulsing

    Approx. 0.05 ml/stroke, pulsing

    Min. pressure

    3 bar

    3 bar

    Contact output with individual stroke detection

    Open collector, 1 contact per stroke

    Open collector, 1 contact per stroke

    Frequency output

    Open collector, up to 10 kHz at maximum flow (parametrisable)

    Open collector, up to 10 kHz at maximum flow (parametrisable)

    Analogue output

    Parameters can be set, max. load 400 Ω

    Parameters can be set, max. load 400 Ω

    Type

    beta 1000 – 0413/0713, gamma/ X 1602 – 0414/0715, gamma/ XL 1608 – 1612

    beta 1604 – 0420, gamma/ X 1604 – 0424, gamma/ XL 1020 – 0450, Sigma/ 1

    Downloads for Flow Meter DULCOFLOW

    More in the Download Centre

    0 Results
    Filter by document type
    Application Example / Reference (0)
    Brochure / Flyer (0)
    Catalogue (0)
    Certificate / Declaration (0)
    Data Sheet (0)
    Drawing / Dimensional Drawing / 3D (0)
    Exploded View / Spare Parts (0)
    Material Safety Data Sheet (0)
    Operating Instructions (0)
    Others (0)
    Press Release (0)
    Publication / Article (0)
    Software (0)
    Wiring Diagram (0)

    Selected filters:

    Matching downloads

    Sort by Document type
    Load more matches ...
    No more matches available!

    Unfortunately, we did not find an appropriate match.

    All words written correctly?
    Search again with fewer or different search terms?

    Please try again later

    Service Unavailable

    The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

    Overview

    Your reliable control unit: unobtrusively measures, monitors and detects faults.

    The device works on the ultrasound measuring principle. It was developed specifically for measuring small pulsating volumetric flows. It is installed around 30 cm downstream of the metering pump, so that there is still sufficient pulsation in the flow. All liquids that conduct ultrasound waves can be measured.

    Your benefits

    • Maximum chemical resistance by the use of PVDF and PTFE
    • No electrical conductivity of the medium is needed
    • Measurement above stroke volumes of approx. 30 µl
    • Detection of gas bubbles in the feed chemical
    • No bottlenecks in the measuring tube. Media with small undissolved particles or with increased viscosity can be measured
    • A 0/4 -20 mA current output and a frequency output are available for remote transmission of the measured values.

    Video

    Application

    Technical Data

    Downloads

    Contact us

    Mr. Vikalp Tripathi

    Managing Director, Heidelberg ProMinent Fluid Controls India Pvt. Ltd.

    »Please send us your request! We will contact you shortly.«

    +91 8023 5788 72  Send request   

    Matching Products

    Practical examples for this product

    ProMinent Newsletter - receive latest news, customized for you! subscribe now