DULCOTEST sensors for conductivity
Graduated measuring ranges 0.01 µS/cm – 2,000 mS/cm
Conductivity sensors for optimum process integration: DULCOTEST sensors meet a wide range of measuring requirements and allow the best solution to any given measuring task to be achieved.
Product description
Online measurement of electrolytic conductivity – with reliable DULCOTEST sensors.
Conductive conductivity Conductive conductivity sensors measure the electrolytic conductivity indirectly via ... more in the glossary sensors measure the electrolytic conductivity indirectly via the charge transfer between two probes immersed in the medium to be measured. The sensor types with cell constants k = 0.01 and k = 0.1 cm-1 are especially suitable for measuring the lowest electrolytic conductivities of < 1 µS/cm in pure and ultra-pure water.
The sensor types with cell constants k=1 cm-1 are used in numerous kinds of water without film-forming components up to 20 mS/cm. The cost-effective sensor range LF(T) is used in clear, chemically uncontaminated water.
The sensor ranges LM(P), CK and CKPt can also be used in chemically contaminated kinds of water and at higher temperatures.
Your benefits
- 27 different sensor types tailored to different requirements and offering optimum performance for money: measuring range, temperature, chemical resistance, contamination tolerance and process integration
- From simple conductometric sensors to high-end sensors based on the inductive measurement principle
- Precise and reliable measurement enables efficient processes and maximum process reliability
- Long service lives and short maintenance intervals reduce downtime and increase the availability of the measured values
- Complete pre-assembled kits containing fitting and sensor for easy, fast and error-free installation
- Prompt delivery for quick replacement
Field of application
The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.
- Metering and dilution of chemicals
- Measuring the concentration of aggressive chemicals
- Washing and cleaning processes, especially CIP (cleaning in place) processes in the food and beverage industry
- Blowdown control in cooling towers
- Control of ultra-clean, clean and potable water generation processes
- Wastewater
Conductivity Sensor LMP 001
Sensor for measurement of the lowest electrolytic conductivities for clear and also chemically contaminated water. With integrated temperature measurement and DIN 4-pin plug. For operation with the controllers DCCa, DACb, DMTa, D1CaYour Benefits
- Measured variable: electrolytic conductivity above 0.01 µS/cm
- Cost-effective sensor for clear, chemically contaminated water
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
Measuring range | 0.01…50 µS/cm |
Cell constant | 0.01 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0...70 °C |
Max. pressure | 16.0 bar (50 °C) |
Sensors | Stainless steel 1.4571 |
Sensor shaft | PP |
Thread | 3/4" |
Installation length | 71 mm |
Process integration | Inline: direct installation into the pipework, bypass: with or without return of the sample water into the process line |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | Clean water applications, monitoring ion exchangers and reverse osmosis systems. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Controllers | Compact DCCa, DACb, DMTa, D1Ca |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LMP 001 | 1020508 |
Conductivity Sensor LMP 001-HT
Sensor for measurement of the lowest electrolytic conductivity for clear and also chemically contaminated water. For high temperatures, with integrated temperature measurement and DIN 4-pin plug. For operation with the controllers DCCa, DACb, DMTa, D1CaYour Benefits
- Measured variable: electrolytic conductivity above 0.01 µS/cm
- Cost-effective sensor for clear, chemically contaminated water
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
- Temperature resistance up to 100 °C
Measuring range | 0.01…50 µS/cm |
Cell constant | 0.01 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0...120 °C |
Max. pressure | 16.0 bar (100 °C) |
Sensors | Stainless steel 1.4571 |
Sensor shaft | PVDF |
Thread | 3/4" |
Installation length | 71 mm |
Process integration | Inline: direct installation into the pipework, bypass: with or without return of the sample water into the process line |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | General applications at higher temperatures, clean water applications, condensate. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Controllers | Compact DCCa, DACb, DMTa, D1Ca |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LMP 001-HT | 1020509 |
Conductivity Sensor LMP 01
Sensor for measurement of low electrolytic conductivities for clear and also chemically contaminated water. With integrated temperature measurement and DIN 4-pin plug. For operation with the controllers DCCa, DACb, DMTa, D1CaYour Benefits
- Measured variable: electrolytic conductivity above 0.1 µS/cm
- Cost-effective sensor for clear, chemically contaminated water
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
Measuring range | 0.1…500 µS/cm |
Cell constant | 0.10 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0 … 70 °C |
Max. pressure | 16.0 bar (50 °C) |
Sensors | Stainless steel 1.4571 |
Sensor shaft | PP |
Thread | 3/4" |
Installation length | 46 mm |
Process integration | Inline: direct installation into the pipework, bypass: with or without return of the sample water into the process line |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | Monitoring ion exchangers, reverse osmosis systems and desalination systems. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Controllers | Compact DCCa, DACb, DMTa, D1Ca |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LMP 01 | 1020510 |
Conductivity Sensor LMP 01-TA
Sensor for measurement of low electrolytic conductivities for clear and also chemically contaminated water. With integrated temperature measurement and DIN 4-pin plug. For operation with the controllers DCCa, DACb, DMTa, D1CaYour Benefits
- Measured variable: electrolytic conductivity above 0.1 µS/cm
- Cost-effective sensor for clear, chemically contaminated water
- Simple installation in tanks and containers by sensor ready mounted in the immersion tube
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
Measuring range | 0.1…500 µS/cm |
Cell constant | 0.10 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0 … 70 °C |
Max. pressure | 16.0 bar (50 °C) |
Sensors | Stainless steel 1.4571 |
Sensor shaft | PP |
Thread | M 28 x 1.5 for TA-LM in-line probe fitting |
Installation length | Max. 1 m |
Process integration | Immersion through an immersion tube |
Electrical Connection | 5 m fixed cable |
Enclosure rating | IP 65 |
Typical applications | Monitoring ion exchangers, reverse osmosis systems and desalination systems. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Controllers | Compact DCCa, DACb, DMTa, D1Ca |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | ||
---|---|---|
LMP 01-TA | Sensor integrated in immersion fitting | 1020512 |
LMP 01-FE | Replacement sensor for LMP 01-TA with 5 m fixed cable | 1020626 |
Conductivity Sensor LMP 01-HT
Sensor for measurement of low electrolytic conductivities for clear and also chemically contaminated water. For high temperatures, with integrated temperature measurement and DIN 4-pin plug. For operation with the controllers DCCa, DACb, DMTa, D1CaYour Benefits
- Measured variable: electrolytic conductivity above 0.1 µm/cm
- Cost-effective sensor for clear, chemically contaminated water
- Temperature resistance up to 100 °C
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
Measuring range | 0.1…500 µS/cm |
Cell constant | 0.10 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0 … 120 °C |
Max. pressure | 16.0 bar (100 °C) |
Sensors | Stainless steel 1.4571 |
Sensor shaft | PVDF |
Thread | 3/4" |
Installation length | 46 mm |
Process integration | Inline: direct installation into the pipework, bypass: with or without return of the sample water into the process line |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | General applications at higher temperatures: industrial, process water, condensate. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Controllers | Compact DCCa, DACb, DMTa, D1Ca |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LMP 01-HT | 1020511 |
Conductivity Sensor LFT 1 FE
Cost-effective sensor for measurement of electrolytic conductivity in clear, uncontaminated water. With integrated temperature measurement and fixed cable connector. For operation with controllers DMTa, D1CaYour Benefits
- Measured variable: electrolytic conductivity above 10 µS/cm
- Cost-effective sensor for all clear uncontaminated water
- Flexible process connection by the use of sensor fittings for standard pH sensors
- Special graphite electrodes, optimised for a highly dynamic measuring range: 0.01-20 mS/cm
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
- Fixed cable on the sensor head for difficult ambient conditions
Measuring range | 0.01…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0 … 80 °C (at 1 bar) |
Max. pressure | 16.0 bar (25 °C) |
Sensors | Special graphite |
Sensor shaft | Epoxy |
Thread | PG 13.5 |
Installation length | 120 ±3 mm |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Electrical Connection | 5 m fixed cable (4 x 0.5 mm2) |
Enclosure rating | IP 65 |
Typical applications | Potable, cooling, industrial water. Sensors of the LF series have only limited applicability for taking measurements in cleaning solutions containing surfactants and media containing solvents. |
Resistance to | Unsuitable for chemically contaminated water and water containing film-forming ingredients |
Compatible controllers | DMTa, D1Ca |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LFT 1FE | 1001374 |
Conductivity Sensor LFTK 1 FE-5m-shd
Cost-effective sensor for measurement of electrolytic conductivity in clear, uncontaminated water. With integrated temperature measurement and fixed cable connector (5 m). For operation with controllers DCCa, DACb, DMTa, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 10 µS/cm
- Cost-effective sensor for all clear uncontaminated water
- Flexible process connection by the use of sensor fittings for standard pH sensors
- Special graphite electrodes, optimised for a highly dynamic measuring range: 0.01-20 mS/cm
- Integrated Pt 1000 for precise temperature compensation in limited temperature ranges replaces separate temperature sensor and the corresponding sensor fitting
- Fixed cable on the sensor head for difficult ambient conditions
Measuring range | 0.01…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | Pt 1000 |
Medium temperature | 0 … 80 °C (at 1 bar) |
Max. pressure | 16.0 bar (25 °C) |
Sensors | Special graphite |
Sensor shaft | Epoxy |
Thread | PG 13.5 |
Installation length | 120 ±3 mm |
Process integration | Bypass: with or without return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Electrical Connection | 5 m fixed cable (4 x 0.25 mm2), screened |
Enclosure rating | IP 65 |
Typical applications | Potable, cooling, industrial water. |
Resistance to | Unsuitable for chemically contaminated water and water containing film-forming ingredients |
Compatible controllers | DCCa, DACb, DMTa, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LFTK 1 FE-5m-shd | 1046132 |
Conductivity Sensor LFTK 1 FE-3m-shd
Cost-effective sensor for measurement of electrolytic conductivity in clear, uncontaminated water. With integrated temperature measurement and fixed cable connector (3 m). For operation with controllers DCCa, DACb, DMTa, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 10 µS/cm
- Cost-effective sensor for all clear uncontaminated water
- Flexible process connection by the use of sensor fittings for standard pH sensors
- Special graphite electrodes, optimised for a highly dynamic measuring range: 0.01-20 mS/cm
- Integrated Pt 1000 for precise temperature compensation in limited temperature ranges replaces separate temperature sensor and the corresponding sensor fitting
- Fixed cable on the sensor head for difficult ambient conditions
Measuring range | 0.01…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | Pt 1000 |
Medium temperature | 0 … 80 °C (at 1 bar) |
Max. pressure | 16.0 bar (25 °C) |
Sensors | Special graphite |
Sensor shaft | Epoxy |
Thread | PG 13.5 |
Installation length | 120 ±3 mm |
Process integration | Bypass: with or without return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Electrical Connection | 3 m fixed cable (4 x 0.25 mm2), screened |
Enclosure rating | IP 65 |
Typical applications | Potable, cooling, industrial water. Sensors of the LF series have only limited applicability for taking measurements in cleaning solutions containing surfactants and media containing solvents. |
Resistance to | Unsuitable for chemically contaminated water and water containing film-forming ingredients |
Compatible controllers | DCCa, DACb, DMTa, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LFTK 1 FE-3m-shd | 1046010 |
Conductivity Sensor LFT 1 DE
Cost-effective sensor for measurement of electrolytic conductivity in clear, uncontaminated water. With integrated temperature measurement and DIN 4-pin plug. For operation with controllers DCCa, DACb, DMTa, D1Ca, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 10 µS/cm
- Cost-effective sensor for all clear, uncontaminated types of water
- Flexible process connection by the use of sensor fittings for standard pH sensors
- Special graphite electrodes, optimised for a highly dynamic measuring range: 0.01-20 mS/cm
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
- DIN 4-pin plug for simple installation
Measuring range | 0.01…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0 … 80 °C (at 1 bar) |
Max. pressure | 16.0 bar (25 °C) |
Sensors | Special graphite |
Sensor shaft | Epoxy |
Thread | PG 13.5 |
Installation length | 120 ±3 mm |
Process integration | Bypass: with or without return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | Potable water, cooling water, industrial process water. Sensors of the LF series have only limited applicability for taking measurements in cleaning solutions containing surfactants and media containing solvents. |
Resistance to | Unsuitable for chemically contaminated water and water containing film-forming ingredients |
Compatible controllers | DCCa, DACb, DMTa, D1Ca, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LFT 1 DE | 1001376 |
Conductivity Sensor LFTK 1 DE
Cost-effective sensor for measurement of electrolytic conductivity in clear, uncontaminated water with integrated temperature measurement and DIN 4-pin plug. For operation with controllers DCCa, DACb, DMTa, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 10 µS/cm
- Cost-effective sensor for all clear uncontaminated water
- Flexible process connection by the use of sensor fittings for standard pH sensors
- Special graphite electrodes, optimised for a highly dynamic measuring range: 0.01-20 mS/cm
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
- DIN 4-pin plug for simple installation
Measuring range | 0.01…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | Pt 1000 |
Medium temperature | 0 … 80 °C (at 1 bar) |
Max. pressure | 16.0 bar (25 °C) |
Sensors | Special graphite |
Sensor shaft | Epoxy |
Thread | PG 13.5 |
Installation length | 120 ±3 mm |
Process integration | Bypass: with or without return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | Potable, cooling, industrial water. Sensors of the LF series have only limited applicability for taking measurements in cleaning solutions containing surfactants and media containing solvents. |
Resistance to | Unsuitable for chemically contaminated water and water containing film-forming ingredients |
Compatible controllers | DCCa, DACb, DMTa, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LFTK 1 DE | 1002822 |
Conductivity sensor LFT 1 1/2"
Cost-effective sensor for measurement of electrolytic conductivity in clear, uncontaminated water. With integrated temperature measurement and DIN 4-pin plug and 1/2-inch screw-in thread. For operation with controllers DCCa, DACb, DMTa, D1Ca, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 10 µS/cm
- Cost-effective sensor for all clear, uncontaminated types of water
- Hydraulic connector with 1/2" thread as an alternative to the corresponding standard design with PG 13.5 thread
- Special graphite electrodes, optimised for a highly dynamic measuring range: 0.01-20 mS/cm
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
- DIN 4-pin plug for simple installation
Measuring range | 0.01…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0 … 80 °C (at 1 bar) |
Max. pressure | 16.0 bar (25 °C) |
Sensors | Special graphite |
Sensor shaft | Epoxy |
Thread | 1/2" |
Installation length | 120 ±3 mm |
Process integration | Bypass: with or without return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | Potable, cooling, industrial water. Sensors of the LF series have only limited applicability for taking measurements in cleaning solutions containing surfactants and media containing solvents. |
Resistance to | Unsuitable for chemically contaminated water and water containing film-forming ingredients |
Compatible controllers | DCCa, DACb, DMTa, D1Ca, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LFT 1 1/2" | 1001378 |
Conductivity sensor LFTK 1 1/2"
Cost-effective sensor for measurement of electrolytic conductivity in clear, uncontaminated water. With integrated temperature measurement and DIN 4-pin plug and 1/2-inch screw-in thread. For operation with controllers DCCa, DACb, DMTa, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 10 µC/cm
- Cost-effective sensor for all clear, uncontaminated types of water
- Hydraulic connector with 1/2" thread as an alternative to the corresponding standard design with PG 13.5 thread
- Special graphite electrodes, optimised for a highly dynamic measuring range: 0.01-20 mS/cm
- Integrated Pt 1000 for precise compensation in limited temperature ranges and with longer cables. Replaces separate temperature sensor and the corresponding sensor fitting
- DIN 4-pin plug for simple installation
Measuring range | 0.01…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | Pt 1000 |
Medium temperature | 0 … 80 °C (at 1 bar) |
Max. pressure | 16.0 bar (25 °C) |
Sensors | Special graphite |
Sensor shaft | Epoxy |
Thread | 1/2" |
Installation length | 120 ±3 mm |
Process integration | Bypass: with or without return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | Potable, cooling, industrial water. Sensors of the LF series have only limited applicability for taking measurements in cleaning solutions containing surfactants and media containing solvents. |
Resistance to | Unsuitable for chemically contaminated water and water containing film-forming ingredients |
Compatible controllers | DCCa, DACb, DMTa, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LFTK 1 1/2" | 1002823 |
Conductivity Sensor CK 1
Sensor for measurement of electrolytic conductivity for clear, chemically contaminated water with higher but constant temperature with DIN 4-pin plug. For operation with controllers DCCa, DACb, DMTa, D1Ca, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 10 µS/cm
- Resistant to water ingredients in target applications thanks to injection-moulded design without adhesive or seals
- High temperature resistance up to 150 °C
Measuring range | 0.01…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | None, only for applications with constant temperature |
Medium temperature | 0 … 150 °C (at 1 bar) |
Max. pressure | 16.0 bar (20 °C) |
Sensors | Special graphite |
Sensor shaft | PES |
Thread | R 1" |
Installation length | 79 mm |
Process integration | Bypass: with or without return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | Cooling, industrial, process water, tank and pipe, cleaning systems in breweries, dairies, media separation. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Compatible controllers | DCCa, DACb, DMTa, D1Ca, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes |
Order no. | |
---|---|
CK 1 | 305605 |
Conductivity Sensor CKPt 1
Sensor for measurement of electrolytic conductivity for clear, chemically contaminated water and higher temperatures. With integrated temperature measurement and DIN 4-pin plug. For operation with controllers DCCa, DACb, DMTa, D1Ca, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 10 µS/cm
- Resistant to water ingredients in target applications thanks to injection-moulded design without adhesive or seals
- High temperature resistance up to 150 °C
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
Measuring range | 0.01…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0 … 150 °C (at 1 bar) |
Max. pressure | 16.0 bar (20 °C) |
Sensors | Special graphite |
Sensor shaft | PES |
Thread | R 1" |
Installation length | 79 mm |
Process integration | Bypass: with or without return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | Cooling, industrial, process water, tank and pipe, cleaning systems in breweries, dairies, media separation. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Compatible controllers | DCCa, DACb, DMTa, D1Ca, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
CKPt 1 | 305606 |
Conductivity Sensor LM 1
Sensor for measurement of electrolytic conductivity for clear and also chemically contaminated water. With DIN 4-pin plug. For operation with controllers DCCa, DACb, DMTa, D1Ca, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 0.1 mS/cm
- Cost-effective sensor for clear, chemically contaminated water
- Resistant to the constituents in the water of the target application
Measuring range | 0.1…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | None, only for applications with constant temperature |
Medium temperature | 0 … 70 °C (at 1 bar) |
Max. pressure | 16.0 bar (50 °C) |
Sensors | Graphite |
Sensor shaft | PP |
Thread | 3/4" |
Installation length | 46 mm |
Process integration | Inline: direct installation into the pipework, bypass: with or without return of the sample water into the process line |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | Potable, cooling, industrial, process water, media separation. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Compatible controllers | DCCa, DACb, DMTa, D1Ca, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes |
Order no. | |
---|---|
LM 1 | 740433 |
Conductivity Sensor LM 1-TA
Sensor for measurement of electrolytic conductivity for clear and also chemically contaminated water. Fully assembled in an immersion fitting. For operation with controllers DCCa, DACb, DMTa, D1Ca, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 0.1 mS/cm
- Cost-effective sensor for clear, chemically contaminated water
- Resistant to the ingredients in the water of the target applications
- Simple installation in tanks, containers etc. by sensor ready mounted in the immersion tube
Measuring range | 0.1…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | None, only for applications with constant temperature |
Medium temperature | 0 … 70 °C (at 1 bar) |
Max. pressure | 16.0 bar (50 °C) |
Sensors | Graphite |
Sensor shaft | PP |
Thread | M 28 x 1.5 for TA-LM in-line probe fitting |
Installation length | Max. 1 m |
Process integration | Tank, channel: Immersion through an immersion tube |
Electrical Connection | 5 m fixed cable, screened |
Enclosure rating | IP 65 |
Typical applications | Potable, cooling, industrial, process water, media separation. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Compatible controllers | DCCa, DACb, DMTa, D1Ca, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes |
Order no. | ||
---|---|---|
LM 1-TA | Sensor integrated in immersion fitting | 1020528 |
LM 1-FE | Replacement sensor for LM 1-TA | 1020627 |
Conductivity Sensor LMP 1
Sensor for measurement of electrolytic conductivity for clear and also chemically contaminated water. With integrated temperature measurement with DIN 4-pin plug. For operation with controllers DCCa, DACb, DMTa, D1Ca, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 0.1 mS/cm
- Cost-effective sensor for clear, chemically contaminated water
- Resistant to the ingredients in the water of the target applications
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
Measuring range | 0.1…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0 … 70 °C (at 1 bar) |
Max. pressure | 16.0 bar (50 °C) |
Sensors | Graphite |
Sensor shaft | PP |
Thread | 3/4" |
Installation length | 46 mm |
Process integration | Inline: direct installation into the pipework, bypass: with or without return of the sample water into the process line |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | Potable, cooling, industrial, process water, media separation. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Compatible controllers | DCCa, DACb, DMTa, D1Ca, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LMP 1 | 1020513 |
Conductivity Sensor LMP 1-TA
Sensor for measurement of electrolytic conductivity for clear and also chemically contaminated water. With integrated temperature measurement, fully assembled in an immersion fitting. For operation with controllers DCCa, DACb, DMTa, D1Ca, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 0.1 mS/cm
- Cost-effective sensor for clear, chemically contaminated water
- Resistant to the ingredients in the water of the target applications
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
- Simple installation in tanks, containers etc. by sensor ready mounted in the immersion tube
Measuring range | 0.1…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0 … 70 °C (at 1 bar) |
Max. pressure | 16.0 bar (50 °C) |
Sensors | Graphite |
Sensor shaft | PP |
Thread | M 28 x 1.5 for TA-LM in-line probe fitting |
Installation length | 1 m |
Process integration | Tank, channel: Immersion through an immersion tube |
Electrical Connection | 5 m fixed cable, screened |
Enclosure rating | IP 65 |
Typical applications | Potable, cooling, industrial, process water, media separation. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Compatible controllers | DCCa, DACb, DMTa, D1Ca, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes |
Order no. | ||
---|---|---|
LMP 1-TA | Sensor integrated in immersion fitting | 1020525 |
LMP 1-FE | Replacement sensor for LMP 1-TA | 1020727 |
Conductivity Sensor LMP 1-HT
Sensor for measurement of electrolytic conductivity for clear and also chemically contaminated water. For high temperatures, with integrated temperature measurement and DIN 4-pin plug. For operation with controllers DCCa, DACb, DMTa, D1Ca, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 0.1 mS/cm
- Cost-effective sensor for clear, chemically contaminated water
- Resistant to the ingredients in the water of the target applications
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
- Temperature resistance up to 100 °C
Measuring range | 0.1…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0 … 120 °C (at 1 bar) |
Max. pressure | 16.0 bar (100 °C) |
Sensors | Graphite |
Sensor shaft | PVDF |
Thread | 3/4" |
Installation length | 46 mm |
Process integration | Inline: direct installation into the pipework, bypass: with or without return of the sample water into the process line |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | General applications at higher temperatures process water, process water from electroplating, media separation, with CIP (cleaning in place). |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Compatible controllers | DCCa, DACb, DMTa, D1Ca, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LMP 1-HT | 1020524 |
Conductivity sensor CCT 1-mA
Sensor for measurement of electrolytic conductivities for clear and also chemically contaminated water. With integrated temperature measurement and factory-calibrated 4...20 mA output signal. For operation with controllers DAC, D1C, AEGIS II, AEGIS X, DULCOMARIN.Your Benefits
- Measured variable: electrolytic conductivity up to 20 mS/cm
- Fail-safe 4-20 mA output signal for flexible connection to measuring equipment with standard 4-20 mA input
- Integrated temperature sensor for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
- Simple connection to a process with the ProMinent bypass fittings BAMa, DGMA, DLGIII and INLI
Measuring range | 0.2…20 mS/cm |
Temperature measurement | NTC, integrated |
Medium temperature | 0 … 50 °C (at 1 bar) |
Max. pressure | 8.0 bar (25 °C) |
Sensor head | PMMA |
Sensors | Special graphite |
Sensor shaft | PVC |
Installation length | 51 mm / 71 mm |
Process integration | Bypass via bypass fittings BAMa, DGMa, DLGIII or installation into G1” PP pipe via sensor fitting INLI |
Electrical Connection | 4-wire cable, 0.25 mm², cable diameter 5.7 |
Supply voltage | 12…36 V DC |
Output signal | 4…20 mA, temperature-compensated, factory-calibrated, electrically isolated |
Enclosure rating | IP 65 |
Typical applications | Cooling, industrial, process water, general water with higher salt content up to 20 mS/cm. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Compatible controllers | DAC, D1C, AEGIS II, AEGIS X, DULCOMARIN |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement, integrated 4...20 mA transducer |
Order no. | |
---|---|
CCT 1-mA-20 mS/cm | 1081545 |
Conductivity sensor ICT 5
Cost-effective inductive conductivity sensor, suitable for high electrolytic conductivities above 200 µS/cm. Also suitable for chemically contaminated water and film-forming media. For installation in pipework
Your Benefits
- Measured variable: electrolytic conductivity. The inductive (non-contact) measuring principle permits applications in chemically contaminated types of water and in film-forming media
- Complete with injection moulded PP sensor head, no apparent bonds, seals
- Measurements at high conductivity values of up to 2,000 mS/cm are possible without interfering polarisation by means of the high measuring range dynamics of the inductive measuring principle
- Simple installation in PVC pipework by bonding the DN 40 adhesive connector supplied into a standard T-piece and screwing in the sensor using the union nut supplied.
- A DN 40 welded connector is optionally available for use in PP pipework
Measuring range | 0.2…2,000 mS/cm |
Cell constant | 6.25 cm-1 |
Measuring accuracy | ±2% based on the measured value ±30 μS/cm |
Temperature sensor | Pt 1000, wetted material Stainless steel 1.4301 |
Medium temperature | -10...80 °C -10...60 °C for installation in PVC pipes, -10...80 °C for installation in PP pipes |
Max. pressure | 10.0 bar at 20 °C, 6.0 bar at 60 °C, 0.0 bar at 80 °C |
Min. pressure | -0.1 bar (-10 … 80 °C) |
Sensor material | PP |
Seals | EPDM |
Electrical Connection | 10 m fixed cable, 7x 0.35 mm² via a terminal |
Enclosure rating | IP 65 |
Typical applications | Contaminated wastewater, blowdown control in cooling towers, control of electroplating and rinsing baths, cleaning in Place (CIP), product monitoring, seawater, brine swimming pools. |
Resistance to | Ingredients in the water of the target application, taking into account compatibility to PP/EPDM, deposit-forming media |
Process integration | With union nut, PVC, 1 1/2 inch female thread, including DN 40 bonded nozzle with 1 1/2 inch male thread for fitting in DN 40 PVC standard pipes (included in the scope of delivery). The corresponding set-in nozzle for fitting in PP standard pipes is available as an accessory |
Controllers | Compact controller DCCa |
Measuring principle, technology | Inductive, 2 coils. Integrated temperature measurement |
Order no. | |
---|---|
ICT 5 | 1095248 |
Conductivity Sensor ICT 5-IMA
Cost-effective inductive conductivity sensor, suitable for high electrolytic conductivities above 200 µS/cm. Also suitable for chemically contaminated water and film-forming media. Completely integrated into an immersion pipeYour Benefits
- Measured variable: electrolytic conductivity. The inductive (non-contact) measuring principle permits applications in chemically contaminated types of water and in film-forming media
- Complete with injection moulded PP sensor head, no apparent bonds, seals
- Measurements at high conductivity values of up to 2,000 mS/cm are possible without interfering polarisation by means of the high measuring range dynamics of the inductive measuring principle
- Simple installation in tanks, containers etc. thanks to sensor ready mounted in the immersion tube
Measuring range | 0.2…2,000 mS/cm |
Cell constant | 6.25 cm-1 |
Measuring accuracy | ±2% based on the measured value ±30 μS/cm |
Temperature sensor | Pt 1000, wetted material Stainless steel 1.4301 |
Medium temperature | -10…60 °C |
Max. pressure | 0.0 bar |
Min. pressure | -0.1 bar (-10 … 60 °C) |
Sensor material | PP |
Immersion pipe material | PP |
Sensor guard material | SS 1.4301, AISI 304 |
Seals | EPDM |
Electrical Connection | 10 m fixed cable, 7x 0.35 mm² via a terminal |
Enclosure rating | IP 65 |
Typical applications | Contaminated wastewater, blowdown control in cooling towers, control of electroplating and rinsing baths, cleaning in Place (CIP), product monitoring, seawater, brine swimming pools. |
Resistance to | Ingredients in the water of the target application, taking into account compatibility to PP/EPDM, deposit-forming media |
Process integration | Immersion with immersion length 1 m |
Controllers | Compact controller DCCa |
Measuring principle, technology | Inductive, 2 coils. Integrated temperature measurement |
Order no. | |
---|---|
ICT 5-IMA | 1095249 |
Conductivity Sensor ICT 2
High-performance inductive conductivity sensor with high dynamic measuring range. Also suitable for types of water with aggressive chemicals and film-forming components. Permitted temperatures up to 125 °C. For installation in pipework, tanks and for immersion in storage tanks
Your Benefits
- Measured variable: electrolytic conductivity. The inductive (non-contact) measuring principle permits applications in chemically contaminated types of water and in film-forming media
- There is no need for adhesive or seals as the sensor is fully embedded in PFA
- Measurements at high conductivity values of up to 2,000 mS/cm are possible without interfering polarisation by means of the high measuring range dynamics of the inductive measuring principle
- Flexible connection to the processes is possible via a flange or immersion pipe with optional accessories
Measuring range | 0.02…2,000 mS/cm |
Cell constant | 1.98 cm-1 |
Measuring accuracy | ± (5 μS/cm + 0.5 % of measured value at T < 100 °C) ± (10 μS/cm + 0.5 % of measured value at T > 100 °C) |
Temperature compensation | Pt 100, class A, completely extrusion-coated |
Medium temperature | 0…125 °C, when used together with D1C, temperature compensation is limited to 100 °C |
Max. pressure | 16.0 bar |
Sensor material | PFA, completely extrusion-coated |
Electrical Connection | 5 m fixed cable, 6x 0.35 mm² via a terminal |
Enclosure rating | IP 67 |
Typical applications | Production processes in the chemical industry, phase separation of product mixtures, determination of concentrations of aggressive chemicals. |
Resistance to | Electrolytic conductivity of > 20 mS/cm, PFA-compatible aggressive chemicals (no concentrated lyes), deposit-forming media |
Process integration | Fitting in pipes, tanks (sideways): G 3/4 stainless steel thread (1.4571) or flange fitting: With the accessories: Stainless steel flange ANSI 2 inch 300 lbs, SS 316L (adaptable to DIN counter flange DN 50 PN 16). |
Controllers | Compact controller DCCa |
Measuring principle, technology | Inductive, 2 coils. Integrated temperature measurement |
Order no. | |
---|---|
ICT 2 | 1023352 |
Conductivity sensor ICT 8-mA
Inductive sensor for the measurement of electrolytic conductivity. Suitable for contaminated water. With integrated temperature correction and factory-calibrated 4...20 mA output signal.Your Benefits
- Measured variable: electrolytic conductivity up to 200 mS/cm without polarisation effect
- The inductive (non-contact) measuring principle permits applications in water with solids content and in film-forming media
- Fail-safe 4-20 mA output signal for flexible connection to measuring equipment with standard 4...20 mA input
- Integrated temperature correction replaces separate temperature sensor and sensor fitting
Measuring range | three configurable measuring ranges 0.2...2.0 mS/cm / 0.5...20 mS/cm / 1...200 mS/cm |
Temperature correction | integrated in the sensor electronics, temperature co-efficient: 1.7%/K |
Medium temperature | max. 50 °C at 1 bar |
Sensor material | PP |
Seals | EPDM |
Installation length | 75 mm |
Electrical Connection | Fixed cable, 6-wire (6x0.25 mm²). The cable length is 2 m between the sensor and 4-20 mA cable transmitter and 10 m between the cable transmitter and monitor. |
Typical applications | Desalination control in cooling towers, contaminated wastewater, control of electroplating and rinsing baths, salt water desalination, adjustment of the salt content in swimming pool water |
Resistance to | Water ingredients in the target application, taking into account compatibility to PP/EPDM and combating film-forming media |
Process integration | 1/2" male thread (BSP) for mounting using flange, |
Compatible controllers | DAC, D1C, AEGIS II, AEGIS X, DULCOMARIN |
Measuring principle, technology | Inductive, 2 coils. Integrated temperature measurement, integrated 4...20 mA transducer |
Order no. | |
---|---|
ICT 8 -mA-200 mS/cm | 1098530 |
Downloads for DULCOTEST sensors for conductivity
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.
Overview
Online measurement of electrolytic conductivity – with reliable DULCOTEST sensors.
Conductive conductivity Conductive conductivity sensors measure the electrolytic conductivity indirectly via ... more in the glossary sensors measure the electrolytic conductivity indirectly via the charge transfer between two probes immersed in the medium to be measured. The sensor types with cell constants k = 0.01 and k = 0.1 cm-1 are especially suitable for measuring the lowest electrolytic conductivities of < 1 µS/cm in pure and ultra-pure water.
The sensor types with cell constants k=1 cm-1 are used in numerous kinds of water without film-forming components up to 20 mS/cm. The cost-effective sensor range LF(T) is used in clear, chemically uncontaminated water.
The sensor ranges LM(P), CK and CKPt can also be used in chemically contaminated kinds of water and at higher temperatures.
Your benefits
- 27 different sensor types tailored to different requirements and offering optimum performance for money: measuring range, temperature, chemical resistance, contamination tolerance and process integration
- From simple conductometric sensors to high-end sensors based on the inductive measurement principle
- Precise and reliable measurement enables efficient processes and maximum process reliability
- Long service lives and short maintenance intervals reduce downtime and increase the availability of the measured values
- Complete pre-assembled kits containing fitting and sensor for easy, fast and error-free installation
- Prompt delivery for quick replacement
Application
Field of application
The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.
- Metering and dilution of chemicals
- Measuring the concentration of aggressive chemicals
- Washing and cleaning processes, especially CIP (cleaning in place) processes in the food and beverage industry
- Blowdown control in cooling towers
- Control of ultra-clean, clean and potable water generation processes
- Wastewater
Technical Data
Conductivity Sensor LMP 001
Sensor for measurement of the lowest electrolytic conductivities for clear and also chemically contaminated water. With integrated temperature measurement and DIN 4-pin plug. For operation with the controllers DCCa, DACb, DMTa, D1CaYour Benefits
- Measured variable: electrolytic conductivity above 0.01 µS/cm
- Cost-effective sensor for clear, chemically contaminated water
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
Measuring range | 0.01…50 µS/cm |
Cell constant | 0.01 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0...70 °C |
Max. pressure | 16.0 bar (50 °C) |
Sensors | Stainless steel 1.4571 |
Sensor shaft | PP |
Thread | 3/4" |
Installation length | 71 mm |
Process integration | Inline: direct installation into the pipework, bypass: with or without return of the sample water into the process line |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | Clean water applications, monitoring ion exchangers and reverse osmosis systems. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Controllers | Compact DCCa, DACb, DMTa, D1Ca |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LMP 001 | 1020508 |
Conductivity Sensor LMP 001-HT
Sensor for measurement of the lowest electrolytic conductivity for clear and also chemically contaminated water. For high temperatures, with integrated temperature measurement and DIN 4-pin plug. For operation with the controllers DCCa, DACb, DMTa, D1CaYour Benefits
- Measured variable: electrolytic conductivity above 0.01 µS/cm
- Cost-effective sensor for clear, chemically contaminated water
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
- Temperature resistance up to 100 °C
Measuring range | 0.01…50 µS/cm |
Cell constant | 0.01 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0...120 °C |
Max. pressure | 16.0 bar (100 °C) |
Sensors | Stainless steel 1.4571 |
Sensor shaft | PVDF |
Thread | 3/4" |
Installation length | 71 mm |
Process integration | Inline: direct installation into the pipework, bypass: with or without return of the sample water into the process line |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | General applications at higher temperatures, clean water applications, condensate. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Controllers | Compact DCCa, DACb, DMTa, D1Ca |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LMP 001-HT | 1020509 |
Conductivity Sensor LMP 01
Sensor for measurement of low electrolytic conductivities for clear and also chemically contaminated water. With integrated temperature measurement and DIN 4-pin plug. For operation with the controllers DCCa, DACb, DMTa, D1CaYour Benefits
- Measured variable: electrolytic conductivity above 0.1 µS/cm
- Cost-effective sensor for clear, chemically contaminated water
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
Measuring range | 0.1…500 µS/cm |
Cell constant | 0.10 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0 … 70 °C |
Max. pressure | 16.0 bar (50 °C) |
Sensors | Stainless steel 1.4571 |
Sensor shaft | PP |
Thread | 3/4" |
Installation length | 46 mm |
Process integration | Inline: direct installation into the pipework, bypass: with or without return of the sample water into the process line |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | Monitoring ion exchangers, reverse osmosis systems and desalination systems. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Controllers | Compact DCCa, DACb, DMTa, D1Ca |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LMP 01 | 1020510 |
Conductivity Sensor LMP 01-TA
Sensor for measurement of low electrolytic conductivities for clear and also chemically contaminated water. With integrated temperature measurement and DIN 4-pin plug. For operation with the controllers DCCa, DACb, DMTa, D1CaYour Benefits
- Measured variable: electrolytic conductivity above 0.1 µS/cm
- Cost-effective sensor for clear, chemically contaminated water
- Simple installation in tanks and containers by sensor ready mounted in the immersion tube
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
Measuring range | 0.1…500 µS/cm |
Cell constant | 0.10 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0 … 70 °C |
Max. pressure | 16.0 bar (50 °C) |
Sensors | Stainless steel 1.4571 |
Sensor shaft | PP |
Thread | M 28 x 1.5 for TA-LM in-line probe fitting |
Installation length | Max. 1 m |
Process integration | Immersion through an immersion tube |
Electrical Connection | 5 m fixed cable |
Enclosure rating | IP 65 |
Typical applications | Monitoring ion exchangers, reverse osmosis systems and desalination systems. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Controllers | Compact DCCa, DACb, DMTa, D1Ca |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | ||
---|---|---|
LMP 01-TA | Sensor integrated in immersion fitting | 1020512 |
LMP 01-FE | Replacement sensor for LMP 01-TA with 5 m fixed cable | 1020626 |
Conductivity Sensor LMP 01-HT
Sensor for measurement of low electrolytic conductivities for clear and also chemically contaminated water. For high temperatures, with integrated temperature measurement and DIN 4-pin plug. For operation with the controllers DCCa, DACb, DMTa, D1CaYour Benefits
- Measured variable: electrolytic conductivity above 0.1 µm/cm
- Cost-effective sensor for clear, chemically contaminated water
- Temperature resistance up to 100 °C
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
Measuring range | 0.1…500 µS/cm |
Cell constant | 0.10 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0 … 120 °C |
Max. pressure | 16.0 bar (100 °C) |
Sensors | Stainless steel 1.4571 |
Sensor shaft | PVDF |
Thread | 3/4" |
Installation length | 46 mm |
Process integration | Inline: direct installation into the pipework, bypass: with or without return of the sample water into the process line |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | General applications at higher temperatures: industrial, process water, condensate. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Controllers | Compact DCCa, DACb, DMTa, D1Ca |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LMP 01-HT | 1020511 |
Conductivity Sensor LFT 1 FE
Cost-effective sensor for measurement of electrolytic conductivity in clear, uncontaminated water. With integrated temperature measurement and fixed cable connector. For operation with controllers DMTa, D1CaYour Benefits
- Measured variable: electrolytic conductivity above 10 µS/cm
- Cost-effective sensor for all clear uncontaminated water
- Flexible process connection by the use of sensor fittings for standard pH sensors
- Special graphite electrodes, optimised for a highly dynamic measuring range: 0.01-20 mS/cm
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
- Fixed cable on the sensor head for difficult ambient conditions
Measuring range | 0.01…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0 … 80 °C (at 1 bar) |
Max. pressure | 16.0 bar (25 °C) |
Sensors | Special graphite |
Sensor shaft | Epoxy |
Thread | PG 13.5 |
Installation length | 120 ±3 mm |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Electrical Connection | 5 m fixed cable (4 x 0.5 mm2) |
Enclosure rating | IP 65 |
Typical applications | Potable, cooling, industrial water. Sensors of the LF series have only limited applicability for taking measurements in cleaning solutions containing surfactants and media containing solvents. |
Resistance to | Unsuitable for chemically contaminated water and water containing film-forming ingredients |
Compatible controllers | DMTa, D1Ca |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LFT 1FE | 1001374 |
Conductivity Sensor LFTK 1 FE-5m-shd
Cost-effective sensor for measurement of electrolytic conductivity in clear, uncontaminated water. With integrated temperature measurement and fixed cable connector (5 m). For operation with controllers DCCa, DACb, DMTa, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 10 µS/cm
- Cost-effective sensor for all clear uncontaminated water
- Flexible process connection by the use of sensor fittings for standard pH sensors
- Special graphite electrodes, optimised for a highly dynamic measuring range: 0.01-20 mS/cm
- Integrated Pt 1000 for precise temperature compensation in limited temperature ranges replaces separate temperature sensor and the corresponding sensor fitting
- Fixed cable on the sensor head for difficult ambient conditions
Measuring range | 0.01…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | Pt 1000 |
Medium temperature | 0 … 80 °C (at 1 bar) |
Max. pressure | 16.0 bar (25 °C) |
Sensors | Special graphite |
Sensor shaft | Epoxy |
Thread | PG 13.5 |
Installation length | 120 ±3 mm |
Process integration | Bypass: with or without return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Electrical Connection | 5 m fixed cable (4 x 0.25 mm2), screened |
Enclosure rating | IP 65 |
Typical applications | Potable, cooling, industrial water. |
Resistance to | Unsuitable for chemically contaminated water and water containing film-forming ingredients |
Compatible controllers | DCCa, DACb, DMTa, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LFTK 1 FE-5m-shd | 1046132 |
Conductivity Sensor LFTK 1 FE-3m-shd
Cost-effective sensor for measurement of electrolytic conductivity in clear, uncontaminated water. With integrated temperature measurement and fixed cable connector (3 m). For operation with controllers DCCa, DACb, DMTa, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 10 µS/cm
- Cost-effective sensor for all clear uncontaminated water
- Flexible process connection by the use of sensor fittings for standard pH sensors
- Special graphite electrodes, optimised for a highly dynamic measuring range: 0.01-20 mS/cm
- Integrated Pt 1000 for precise temperature compensation in limited temperature ranges replaces separate temperature sensor and the corresponding sensor fitting
- Fixed cable on the sensor head for difficult ambient conditions
Measuring range | 0.01…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | Pt 1000 |
Medium temperature | 0 … 80 °C (at 1 bar) |
Max. pressure | 16.0 bar (25 °C) |
Sensors | Special graphite |
Sensor shaft | Epoxy |
Thread | PG 13.5 |
Installation length | 120 ±3 mm |
Process integration | Bypass: with or without return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Electrical Connection | 3 m fixed cable (4 x 0.25 mm2), screened |
Enclosure rating | IP 65 |
Typical applications | Potable, cooling, industrial water. Sensors of the LF series have only limited applicability for taking measurements in cleaning solutions containing surfactants and media containing solvents. |
Resistance to | Unsuitable for chemically contaminated water and water containing film-forming ingredients |
Compatible controllers | DCCa, DACb, DMTa, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LFTK 1 FE-3m-shd | 1046010 |
Conductivity Sensor LFT 1 DE
Cost-effective sensor for measurement of electrolytic conductivity in clear, uncontaminated water. With integrated temperature measurement and DIN 4-pin plug. For operation with controllers DCCa, DACb, DMTa, D1Ca, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 10 µS/cm
- Cost-effective sensor for all clear, uncontaminated types of water
- Flexible process connection by the use of sensor fittings for standard pH sensors
- Special graphite electrodes, optimised for a highly dynamic measuring range: 0.01-20 mS/cm
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
- DIN 4-pin plug for simple installation
Measuring range | 0.01…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0 … 80 °C (at 1 bar) |
Max. pressure | 16.0 bar (25 °C) |
Sensors | Special graphite |
Sensor shaft | Epoxy |
Thread | PG 13.5 |
Installation length | 120 ±3 mm |
Process integration | Bypass: with or without return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | Potable water, cooling water, industrial process water. Sensors of the LF series have only limited applicability for taking measurements in cleaning solutions containing surfactants and media containing solvents. |
Resistance to | Unsuitable for chemically contaminated water and water containing film-forming ingredients |
Compatible controllers | DCCa, DACb, DMTa, D1Ca, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LFT 1 DE | 1001376 |
Conductivity Sensor LFTK 1 DE
Cost-effective sensor for measurement of electrolytic conductivity in clear, uncontaminated water with integrated temperature measurement and DIN 4-pin plug. For operation with controllers DCCa, DACb, DMTa, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 10 µS/cm
- Cost-effective sensor for all clear uncontaminated water
- Flexible process connection by the use of sensor fittings for standard pH sensors
- Special graphite electrodes, optimised for a highly dynamic measuring range: 0.01-20 mS/cm
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
- DIN 4-pin plug for simple installation
Measuring range | 0.01…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | Pt 1000 |
Medium temperature | 0 … 80 °C (at 1 bar) |
Max. pressure | 16.0 bar (25 °C) |
Sensors | Special graphite |
Sensor shaft | Epoxy |
Thread | PG 13.5 |
Installation length | 120 ±3 mm |
Process integration | Bypass: with or without return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | Potable, cooling, industrial water. Sensors of the LF series have only limited applicability for taking measurements in cleaning solutions containing surfactants and media containing solvents. |
Resistance to | Unsuitable for chemically contaminated water and water containing film-forming ingredients |
Compatible controllers | DCCa, DACb, DMTa, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LFTK 1 DE | 1002822 |
Conductivity sensor LFT 1 1/2"
Cost-effective sensor for measurement of electrolytic conductivity in clear, uncontaminated water. With integrated temperature measurement and DIN 4-pin plug and 1/2-inch screw-in thread. For operation with controllers DCCa, DACb, DMTa, D1Ca, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 10 µS/cm
- Cost-effective sensor for all clear, uncontaminated types of water
- Hydraulic connector with 1/2" thread as an alternative to the corresponding standard design with PG 13.5 thread
- Special graphite electrodes, optimised for a highly dynamic measuring range: 0.01-20 mS/cm
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
- DIN 4-pin plug for simple installation
Measuring range | 0.01…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0 … 80 °C (at 1 bar) |
Max. pressure | 16.0 bar (25 °C) |
Sensors | Special graphite |
Sensor shaft | Epoxy |
Thread | 1/2" |
Installation length | 120 ±3 mm |
Process integration | Bypass: with or without return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | Potable, cooling, industrial water. Sensors of the LF series have only limited applicability for taking measurements in cleaning solutions containing surfactants and media containing solvents. |
Resistance to | Unsuitable for chemically contaminated water and water containing film-forming ingredients |
Compatible controllers | DCCa, DACb, DMTa, D1Ca, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LFT 1 1/2" | 1001378 |
Conductivity sensor LFTK 1 1/2"
Cost-effective sensor for measurement of electrolytic conductivity in clear, uncontaminated water. With integrated temperature measurement and DIN 4-pin plug and 1/2-inch screw-in thread. For operation with controllers DCCa, DACb, DMTa, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 10 µC/cm
- Cost-effective sensor for all clear, uncontaminated types of water
- Hydraulic connector with 1/2" thread as an alternative to the corresponding standard design with PG 13.5 thread
- Special graphite electrodes, optimised for a highly dynamic measuring range: 0.01-20 mS/cm
- Integrated Pt 1000 for precise compensation in limited temperature ranges and with longer cables. Replaces separate temperature sensor and the corresponding sensor fitting
- DIN 4-pin plug for simple installation
Measuring range | 0.01…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | Pt 1000 |
Medium temperature | 0 … 80 °C (at 1 bar) |
Max. pressure | 16.0 bar (25 °C) |
Sensors | Special graphite |
Sensor shaft | Epoxy |
Thread | 1/2" |
Installation length | 120 ±3 mm |
Process integration | Bypass: with or without return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | Potable, cooling, industrial water. Sensors of the LF series have only limited applicability for taking measurements in cleaning solutions containing surfactants and media containing solvents. |
Resistance to | Unsuitable for chemically contaminated water and water containing film-forming ingredients |
Compatible controllers | DCCa, DACb, DMTa, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LFTK 1 1/2" | 1002823 |
Conductivity Sensor CK 1
Sensor for measurement of electrolytic conductivity for clear, chemically contaminated water with higher but constant temperature with DIN 4-pin plug. For operation with controllers DCCa, DACb, DMTa, D1Ca, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 10 µS/cm
- Resistant to water ingredients in target applications thanks to injection-moulded design without adhesive or seals
- High temperature resistance up to 150 °C
Measuring range | 0.01…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | None, only for applications with constant temperature |
Medium temperature | 0 … 150 °C (at 1 bar) |
Max. pressure | 16.0 bar (20 °C) |
Sensors | Special graphite |
Sensor shaft | PES |
Thread | R 1" |
Installation length | 79 mm |
Process integration | Bypass: with or without return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | Cooling, industrial, process water, tank and pipe, cleaning systems in breweries, dairies, media separation. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Compatible controllers | DCCa, DACb, DMTa, D1Ca, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes |
Order no. | |
---|---|
CK 1 | 305605 |
Conductivity Sensor CKPt 1
Sensor for measurement of electrolytic conductivity for clear, chemically contaminated water and higher temperatures. With integrated temperature measurement and DIN 4-pin plug. For operation with controllers DCCa, DACb, DMTa, D1Ca, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 10 µS/cm
- Resistant to water ingredients in target applications thanks to injection-moulded design without adhesive or seals
- High temperature resistance up to 150 °C
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
Measuring range | 0.01…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0 … 150 °C (at 1 bar) |
Max. pressure | 16.0 bar (20 °C) |
Sensors | Special graphite |
Sensor shaft | PES |
Thread | R 1" |
Installation length | 79 mm |
Process integration | Bypass: with or without return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | Cooling, industrial, process water, tank and pipe, cleaning systems in breweries, dairies, media separation. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Compatible controllers | DCCa, DACb, DMTa, D1Ca, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
CKPt 1 | 305606 |
Conductivity Sensor LM 1
Sensor for measurement of electrolytic conductivity for clear and also chemically contaminated water. With DIN 4-pin plug. For operation with controllers DCCa, DACb, DMTa, D1Ca, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 0.1 mS/cm
- Cost-effective sensor for clear, chemically contaminated water
- Resistant to the constituents in the water of the target application
Measuring range | 0.1…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | None, only for applications with constant temperature |
Medium temperature | 0 … 70 °C (at 1 bar) |
Max. pressure | 16.0 bar (50 °C) |
Sensors | Graphite |
Sensor shaft | PP |
Thread | 3/4" |
Installation length | 46 mm |
Process integration | Inline: direct installation into the pipework, bypass: with or without return of the sample water into the process line |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | Potable, cooling, industrial, process water, media separation. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Compatible controllers | DCCa, DACb, DMTa, D1Ca, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes |
Order no. | |
---|---|
LM 1 | 740433 |
Conductivity Sensor LM 1-TA
Sensor for measurement of electrolytic conductivity for clear and also chemically contaminated water. Fully assembled in an immersion fitting. For operation with controllers DCCa, DACb, DMTa, D1Ca, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 0.1 mS/cm
- Cost-effective sensor for clear, chemically contaminated water
- Resistant to the ingredients in the water of the target applications
- Simple installation in tanks, containers etc. by sensor ready mounted in the immersion tube
Measuring range | 0.1…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | None, only for applications with constant temperature |
Medium temperature | 0 … 70 °C (at 1 bar) |
Max. pressure | 16.0 bar (50 °C) |
Sensors | Graphite |
Sensor shaft | PP |
Thread | M 28 x 1.5 for TA-LM in-line probe fitting |
Installation length | Max. 1 m |
Process integration | Tank, channel: Immersion through an immersion tube |
Electrical Connection | 5 m fixed cable, screened |
Enclosure rating | IP 65 |
Typical applications | Potable, cooling, industrial, process water, media separation. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Compatible controllers | DCCa, DACb, DMTa, D1Ca, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes |
Order no. | ||
---|---|---|
LM 1-TA | Sensor integrated in immersion fitting | 1020528 |
LM 1-FE | Replacement sensor for LM 1-TA | 1020627 |
Conductivity Sensor LMP 1
Sensor for measurement of electrolytic conductivity for clear and also chemically contaminated water. With integrated temperature measurement with DIN 4-pin plug. For operation with controllers DCCa, DACb, DMTa, D1Ca, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 0.1 mS/cm
- Cost-effective sensor for clear, chemically contaminated water
- Resistant to the ingredients in the water of the target applications
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
Measuring range | 0.1…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0 … 70 °C (at 1 bar) |
Max. pressure | 16.0 bar (50 °C) |
Sensors | Graphite |
Sensor shaft | PP |
Thread | 3/4" |
Installation length | 46 mm |
Process integration | Inline: direct installation into the pipework, bypass: with or without return of the sample water into the process line |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | Potable, cooling, industrial, process water, media separation. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Compatible controllers | DCCa, DACb, DMTa, D1Ca, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LMP 1 | 1020513 |
Conductivity Sensor LMP 1-TA
Sensor for measurement of electrolytic conductivity for clear and also chemically contaminated water. With integrated temperature measurement, fully assembled in an immersion fitting. For operation with controllers DCCa, DACb, DMTa, D1Ca, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 0.1 mS/cm
- Cost-effective sensor for clear, chemically contaminated water
- Resistant to the ingredients in the water of the target applications
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
- Simple installation in tanks, containers etc. by sensor ready mounted in the immersion tube
Measuring range | 0.1…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0 … 70 °C (at 1 bar) |
Max. pressure | 16.0 bar (50 °C) |
Sensors | Graphite |
Sensor shaft | PP |
Thread | M 28 x 1.5 for TA-LM in-line probe fitting |
Installation length | 1 m |
Process integration | Tank, channel: Immersion through an immersion tube |
Electrical Connection | 5 m fixed cable, screened |
Enclosure rating | IP 65 |
Typical applications | Potable, cooling, industrial, process water, media separation. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Compatible controllers | DCCa, DACb, DMTa, D1Ca, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes |
Order no. | ||
---|---|---|
LMP 1-TA | Sensor integrated in immersion fitting | 1020525 |
LMP 1-FE | Replacement sensor for LMP 1-TA | 1020727 |
Conductivity Sensor LMP 1-HT
Sensor for measurement of electrolytic conductivity for clear and also chemically contaminated water. For high temperatures, with integrated temperature measurement and DIN 4-pin plug. For operation with controllers DCCa, DACb, DMTa, D1Ca, AEGIS II, diaLog XYour Benefits
- Measured variable: electrolytic conductivity above 0.1 mS/cm
- Cost-effective sensor for clear, chemically contaminated water
- Resistant to the ingredients in the water of the target applications
- Integrated Pt 100 for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
- Temperature resistance up to 100 °C
Measuring range | 0.1…20 mS/cm |
Cell constant | 1.00 cm-1 ±5 % |
Temperature measurement | Pt 100 |
Medium temperature | 0 … 120 °C (at 1 bar) |
Max. pressure | 16.0 bar (100 °C) |
Sensors | Graphite |
Sensor shaft | PVDF |
Thread | 3/4" |
Installation length | 46 mm |
Process integration | Inline: direct installation into the pipework, bypass: with or without return of the sample water into the process line |
Electrical Connection | DIN 4-pin angle plug |
Enclosure rating | IP 65 |
Typical applications | General applications at higher temperatures process water, process water from electroplating, media separation, with CIP (cleaning in place). |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Compatible controllers | DCCa, DACb, DMTa, D1Ca, AEGIS II, AEGIS X |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement |
Order no. | |
---|---|
LMP 1-HT | 1020524 |
Conductivity sensor CCT 1-mA
Sensor for measurement of electrolytic conductivities for clear and also chemically contaminated water. With integrated temperature measurement and factory-calibrated 4...20 mA output signal. For operation with controllers DAC, D1C, AEGIS II, AEGIS X, DULCOMARIN.Your Benefits
- Measured variable: electrolytic conductivity up to 20 mS/cm
- Fail-safe 4-20 mA output signal for flexible connection to measuring equipment with standard 4-20 mA input
- Integrated temperature sensor for temperature compensation replaces separate temperature sensor and the corresponding sensor fitting
- Simple connection to a process with the ProMinent bypass fittings BAMa, DGMA, DLGIII and INLI
Measuring range | 0.2…20 mS/cm |
Temperature measurement | NTC, integrated |
Medium temperature | 0 … 50 °C (at 1 bar) |
Max. pressure | 8.0 bar (25 °C) |
Sensor head | PMMA |
Sensors | Special graphite |
Sensor shaft | PVC |
Installation length | 51 mm / 71 mm |
Process integration | Bypass via bypass fittings BAMa, DGMa, DLGIII or installation into G1” PP pipe via sensor fitting INLI |
Electrical Connection | 4-wire cable, 0.25 mm², cable diameter 5.7 |
Supply voltage | 12…36 V DC |
Output signal | 4…20 mA, temperature-compensated, factory-calibrated, electrically isolated |
Enclosure rating | IP 65 |
Typical applications | Cooling, industrial, process water, general water with higher salt content up to 20 mS/cm. |
Resistance to | Ingredients in the water of the target application, taking into account the compatibility of the material |
Compatible controllers | DAC, D1C, AEGIS II, AEGIS X, DULCOMARIN |
Measuring principle, technology | Conductive, 2 electrodes. Integrated temperature measurement, integrated 4...20 mA transducer |
Order no. | |
---|---|
CCT 1-mA-20 mS/cm | 1081545 |
Conductivity sensor ICT 5
Cost-effective inductive conductivity sensor, suitable for high electrolytic conductivities above 200 µS/cm. Also suitable for chemically contaminated water and film-forming media. For installation in pipework
Your Benefits
- Measured variable: electrolytic conductivity. The inductive (non-contact) measuring principle permits applications in chemically contaminated types of water and in film-forming media
- Complete with injection moulded PP sensor head, no apparent bonds, seals
- Measurements at high conductivity values of up to 2,000 mS/cm are possible without interfering polarisation by means of the high measuring range dynamics of the inductive measuring principle
- Simple installation in PVC pipework by bonding the DN 40 adhesive connector supplied into a standard T-piece and screwing in the sensor using the union nut supplied.
- A DN 40 welded connector is optionally available for use in PP pipework
Measuring range | 0.2…2,000 mS/cm |
Cell constant | 6.25 cm-1 |
Measuring accuracy | ±2% based on the measured value ±30 μS/cm |
Temperature sensor | Pt 1000, wetted material Stainless steel 1.4301 |
Medium temperature | -10...80 °C -10...60 °C for installation in PVC pipes, -10...80 °C for installation in PP pipes |
Max. pressure | 10.0 bar at 20 °C, 6.0 bar at 60 °C, 0.0 bar at 80 °C |
Min. pressure | -0.1 bar (-10 … 80 °C) |
Sensor material | PP |
Seals | EPDM |
Electrical Connection | 10 m fixed cable, 7x 0.35 mm² via a terminal |
Enclosure rating | IP 65 |
Typical applications | Contaminated wastewater, blowdown control in cooling towers, control of electroplating and rinsing baths, cleaning in Place (CIP), product monitoring, seawater, brine swimming pools. |
Resistance to | Ingredients in the water of the target application, taking into account compatibility to PP/EPDM, deposit-forming media |
Process integration | With union nut, PVC, 1 1/2 inch female thread, including DN 40 bonded nozzle with 1 1/2 inch male thread for fitting in DN 40 PVC standard pipes (included in the scope of delivery). The corresponding set-in nozzle for fitting in PP standard pipes is available as an accessory |
Controllers | Compact controller DCCa |
Measuring principle, technology | Inductive, 2 coils. Integrated temperature measurement |
Order no. | |
---|---|
ICT 5 | 1095248 |
Conductivity Sensor ICT 5-IMA
Cost-effective inductive conductivity sensor, suitable for high electrolytic conductivities above 200 µS/cm. Also suitable for chemically contaminated water and film-forming media. Completely integrated into an immersion pipeYour Benefits
- Measured variable: electrolytic conductivity. The inductive (non-contact) measuring principle permits applications in chemically contaminated types of water and in film-forming media
- Complete with injection moulded PP sensor head, no apparent bonds, seals
- Measurements at high conductivity values of up to 2,000 mS/cm are possible without interfering polarisation by means of the high measuring range dynamics of the inductive measuring principle
- Simple installation in tanks, containers etc. thanks to sensor ready mounted in the immersion tube
Measuring range | 0.2…2,000 mS/cm |
Cell constant | 6.25 cm-1 |
Measuring accuracy | ±2% based on the measured value ±30 μS/cm |
Temperature sensor | Pt 1000, wetted material Stainless steel 1.4301 |
Medium temperature | -10…60 °C |
Max. pressure | 0.0 bar |
Min. pressure | -0.1 bar (-10 … 60 °C) |
Sensor material | PP |
Immersion pipe material | PP |
Sensor guard material | SS 1.4301, AISI 304 |
Seals | EPDM |
Electrical Connection | 10 m fixed cable, 7x 0.35 mm² via a terminal |
Enclosure rating | IP 65 |
Typical applications | Contaminated wastewater, blowdown control in cooling towers, control of electroplating and rinsing baths, cleaning in Place (CIP), product monitoring, seawater, brine swimming pools. |
Resistance to | Ingredients in the water of the target application, taking into account compatibility to PP/EPDM, deposit-forming media |
Process integration | Immersion with immersion length 1 m |
Controllers | Compact controller DCCa |
Measuring principle, technology | Inductive, 2 coils. Integrated temperature measurement |
Order no. | |
---|---|
ICT 5-IMA | 1095249 |
Conductivity Sensor ICT 2
High-performance inductive conductivity sensor with high dynamic measuring range. Also suitable for types of water with aggressive chemicals and film-forming components. Permitted temperatures up to 125 °C. For installation in pipework, tanks and for immersion in storage tanks
Your Benefits
- Measured variable: electrolytic conductivity. The inductive (non-contact) measuring principle permits applications in chemically contaminated types of water and in film-forming media
- There is no need for adhesive or seals as the sensor is fully embedded in PFA
- Measurements at high conductivity values of up to 2,000 mS/cm are possible without interfering polarisation by means of the high measuring range dynamics of the inductive measuring principle
- Flexible connection to the processes is possible via a flange or immersion pipe with optional accessories
Measuring range | 0.02…2,000 mS/cm |
Cell constant | 1.98 cm-1 |
Measuring accuracy | ± (5 μS/cm + 0.5 % of measured value at T < 100 °C) ± (10 μS/cm + 0.5 % of measured value at T > 100 °C) |
Temperature compensation | Pt 100, class A, completely extrusion-coated |
Medium temperature | 0…125 °C, when used together with D1C, temperature compensation is limited to 100 °C |
Max. pressure | 16.0 bar |
Sensor material | PFA, completely extrusion-coated |
Electrical Connection | 5 m fixed cable, 6x 0.35 mm² via a terminal |
Enclosure rating | IP 67 |
Typical applications | Production processes in the chemical industry, phase separation of product mixtures, determination of concentrations of aggressive chemicals. |
Resistance to | Electrolytic conductivity of > 20 mS/cm, PFA-compatible aggressive chemicals (no concentrated lyes), deposit-forming media |
Process integration | Fitting in pipes, tanks (sideways): G 3/4 stainless steel thread (1.4571) or flange fitting: With the accessories: Stainless steel flange ANSI 2 inch 300 lbs, SS 316L (adaptable to DIN counter flange DN 50 PN 16). |
Controllers | Compact controller DCCa |
Measuring principle, technology | Inductive, 2 coils. Integrated temperature measurement |
Order no. | |
---|---|
ICT 2 | 1023352 |
Conductivity sensor ICT 8-mA
Inductive sensor for the measurement of electrolytic conductivity. Suitable for contaminated water. With integrated temperature correction and factory-calibrated 4...20 mA output signal.Your Benefits
- Measured variable: electrolytic conductivity up to 200 mS/cm without polarisation effect
- The inductive (non-contact) measuring principle permits applications in water with solids content and in film-forming media
- Fail-safe 4-20 mA output signal for flexible connection to measuring equipment with standard 4...20 mA input
- Integrated temperature correction replaces separate temperature sensor and sensor fitting
Measuring range | three configurable measuring ranges 0.2...2.0 mS/cm / 0.5...20 mS/cm / 1...200 mS/cm |
Temperature correction | integrated in the sensor electronics, temperature co-efficient: 1.7%/K |
Medium temperature | max. 50 °C at 1 bar |
Sensor material | PP |
Seals | EPDM |
Installation length | 75 mm |
Electrical Connection | Fixed cable, 6-wire (6x0.25 mm²). The cable length is 2 m between the sensor and 4-20 mA cable transmitter and 10 m between the cable transmitter and monitor. |
Typical applications | Desalination control in cooling towers, contaminated wastewater, control of electroplating and rinsing baths, salt water desalination, adjustment of the salt content in swimming pool water |
Resistance to | Water ingredients in the target application, taking into account compatibility to PP/EPDM and combating film-forming media |
Process integration | 1/2" male thread (BSP) for mounting using flange, |
Compatible controllers | DAC, D1C, AEGIS II, AEGIS X, DULCOMARIN |
Measuring principle, technology | Inductive, 2 coils. Integrated temperature measurement, integrated 4...20 mA transducer |
Order no. | |
---|---|
ICT 8 -mA-200 mS/cm | 1098530 |
Downloads
Downloads for DULCOTEST sensors for conductivity
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.
Contact us
Mr. Vikalp Tripathi