DULCOTEST pH sensors
Graduated pH measuring ranges 0 – 14
pH measurements with DULCOTEST sensors: Precise, reliable and application-adapted measured values in real-time. Control, regulate and monitor chemical processes with the aid of precise measured values.
Product description
Reliable online measurement of pH values – with DULCOTEST sensors
The online measurement and adjustment of pH values must be as accurate, fast and reliable as possible and provide good availability of the measured values, be it for the monitoring, control or regulation of chemical processes.
Our product line of DULCOTEST pH sensors provides a wide range of pH sensors for different measuring tasks.
Our pH sensors are manufactured to very strict quality controls (e.g. in accordance with RoHS guidelines). Routine steps are automated but critical steps are carried out manually under expert supervision. In this way we achieve the best reproducible quality and cost reduction.
Your benefits
- Precise and reliable pH measurement enables efficient processes and excellent process reliability
- The wide choice of sensor types with different constructions makes them reliable components in many applications
- A long service life is achieved through the use of the best quality materials for the glass and diaphragms, a stable reference system and optimised production. This minimises both downtime and maintenance
- With short storage times and fast delivery, your pH sensors can be up and running very quickly and you can make maximum use of their service life (all glass sensors start to age as soon as they leave production)
- Wide range of special versions for fitting length, cable length and plugs for made-to-measure connection to your process
- Unique label for OEM partners
Field of application
The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.
- Chemical processes
- Chemically contaminated water
- Swimming pool water, potable water
- Process water
- Cooling water, wastewater
- Seawater
- Suspensions, sludge, emulsions
- Exhaust air scrubber, semiconductor industry, electroplating
Technical Details
- Selection of sensor type according to the application
- The insertion angle must be > 15° from the horizontal (except with PHEK-L: horizontal to vertical)
- Maximum flow < 0.8 m/s
- With cable lengths > 10 m, use the 4-20 mA transducer type PHV1
- Calibration using quality buffer solutions
pH Sensor PHES 112 SE
pH sensor optimised for use in potable water treatment, swimming pools/hot tubs at up to 60 °C/3 bar
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Diaphragm and reference system optimised for use in swimming pools and for potable water
- Ceramic diaphragm with special material, optimised size and optimised pore diameter
- Long service life due to reduced diffusion ('bleeding') of the electrolyte
- Long service life due to the material, which is inert to aggressive disinfectants
- Stable reference system
- Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…60 °C |
Max. pressure | 3.0 bar |
Min. conductivity | 150 µS/cm |
Electrolyte | Gel containing potassium chloride |
Diaphragm | Ceramic |
Sensor shaft | Glass |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | All DULCOMETER controllers |
Typical applications | Swimming pools, whirlpools, potable water |
Resistance to | Disinfectant |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, gel electrolyte, ceramic diaphragm, separate temperature measurement for temperature compensation needed |
Installation length | Order no. | |
---|---|---|
PHES-112-SE SLg100 | 100 ±3 mm | 1051745 |
PHES 112 SE | 120 ±3 mm | 150702 |
PHES-112-SE SLg225 | 225 ±3 mm | 150092 |
pH Sensor PHES 112 SE 3D
pH sensor optimised for use in potable water treatment, swimming pools/hot tubs and at low electrolytic conductivities of up to 60 °C/3 bar
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Diaphragm and reference system optimised for use in swimming pools
- Ceramic diaphragm with special material, optimised size and optimised pore diameter
- Three ceramic diaphragms optimised for low electrolytic conductivities
- Long service life due to reduced diffusion ('bleeding') of the electrolyte
- Long service life due to the material, which is inert to aggressive disinfectants
- Stable reference system
- Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…60 °C |
Max. pressure | 3.0 bar |
Min. conductivity | 50 µS/cm |
Electrolyte | Gel containing potassium chloride |
Diaphragm | 3 ceramic diaphragms |
Sensor shaft | Glass |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | all DULCOMETER controllers |
Typical applications | Low conductivity water. |
Resistance to | Disinfectant |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, gel electrolyte, ceramic diaphragm, separate temperature measurement for temperature compensation needed |
Installation length | Order no. | |
---|---|---|
PHES 112 SE 3D | 120 ±3 mm | 1045759 |
pH Sensor PHEP 112 SE
pH sensor optimised for use with clear process water and conditions of up to 80 °C/6 bar
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Diaphragm and reference system optimised for exacting process requirements
- Ceramic diaphragm with special material, optimised size and optimised pore diameter
- Long service life due to reduced diffusion ('bleeding') of the electrolyte
- Long service life due to the material, which is inert to aggressive disinfectants
- Stable reference system for high pressure/temperature requirements
- Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…80 °C |
Max. pressure | 6.0 bar |
Min. conductivity | 150 µS/cm |
Electrolyte | Gel containing potassium chloride |
Diaphragm | Ceramic |
Sensor shaft | Glass |
Shaft diameter | 15 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | All DULCOMETER controllers |
Typical applications | Swimming pools during pressurisation for higher temperatures and pressures, potable and industrial water, electroplating, chemical industries. |
Resistance to | Disinfectant |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, gel electrolyte, ceramic diaphragm, separate temperature measurement for temperature compensation needed |
Installation length | Order no. | |
---|---|---|
PHEP 112 SE | 120 ±3 mm | 150041 |
PHEP 112 SE SLg100 | 100 ±3 mm | 150951 |
pH Sensor PHEP-H 314 SE
pH sensor optimised for use with clear process water, specifically for alkaline process solutions at high temperatures of up to 100 °C
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Diaphragm and reference system optimised for exacting process requirements
- Optimised pH-sensitive glass for high alkali content and high temperatures
- Long service life / excellent precision: Measurement at a high pH value of up to 14
- Long service life: at high temperatures of up to 100 °C
- Stable reference system for high pressure/temperature requirements
- Twist protection for the sensor cable connected. This means that the cables can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 3…14 |
Temperature | 0…100 °C |
Max. pressure | 6.0 bar (25 °C), 3.0 bar (100 °C) |
Min. conductivity | 150 µS/cm |
Electrolyte | Gel containing potassium chloride with KCI reservoir |
Diaphragm | Ceramic |
Sensor shaft | Glass |
Shaft diameter | 15 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | All DULCOMETER controllers |
Typical applications | Monitoring or control of chemical processes with neutral to highly-alkaline media and temperatures up to 100 °C. |
Resistance to | Disinfectant, high alkalinity |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, highly alkaline tempered glass, ceramic diaphragm, gel electrolyte, separate temperature measurement for temperature compensation needed |
Order no. | |
---|---|
PHEP-H 314 SE | 1024882 |
pH Sensor PHEI 112 SE
Reliable online measurement of pH values in industrial wastewater/water - with DULCOTEST sensorsYour Benefits
- Solid high-grade plastic housing with integrated process connection for direct installation in the process with ½" and ¾" NPT thread
- Large dirt-repellent Teflon diaphragm protects against unwanted blocking of the reference
- Double junction reference system for stability with chemically polluted water
- Large electrolyte reservoir for long service lives
pH-range | 1…12 |
Temperature | 0…80 °C |
Max. pressure | 6.0 bar |
Min. conductivity | 50 µS/cm |
Electrolyte | Gel containing potassium chloride with a large KCI reservoir of gel |
Diaphragm | 1 x PTFE ring diaphragm and 1x ceramic diaphragm |
Sensor shaft | Plastic |
Shaft diameter | 17 ±0.2 mm (below the ½” NPT thread), 22 ±0.2 mm (below the ¾” thread) |
Installation length | 20 ±0.2 mm (from the lower end of the ½” thread), 60 ±0.2 mm (from the lower end of the ¾” thread) |
Fitting position | Vertical up to +25° |
Thread | ½” and ¾” NPT thread |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | all DULCOMETER controllers |
Typical applications | Municipal and industrial wastewater Cooling water, process water, water in the chemical industry and paper making, generally for water with a solid matter fraction. |
Resistance to | Disinfectant, solids content (turbid water), water-soluble chemicals |
Measuring principle, technology | direct potentiometric measurement, 2 probes, double junction, gel electrolyte, large Teflon diaphragm, separate temperature measurement for temperature compensation needed |
Order no. | |
---|---|
PHEI 112 SE | 1076610 |
pH Sensor PHER 112 SE
pH sensor optimised for use in contaminated water containing solids and for low conductivity of > 50 μS/cm at up to 80 °C/6 bar
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- The large dirt-repellent Teflon® diaphragm prevents the reference system from becoming blocked up
- Long service life when solids are present
- High-viscosity electrolyte combined with a salt reservoir prevents the electrolyte from 'bleeding'
- Long service life without drifts when there is clear water with low conductivity
- Twist protection for the sensor cable connected. This means that the cables can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…80 °C |
Max. pressure | 6.0 bar |
Min. conductivity | 50 µS/cm |
Electrolyte | Gel containing potassium chloride with KCI reservoir |
Diaphragm | PTFE ring diaphragm |
Sensor shaft | Glass |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | All DULCOMETER controllers |
Typical applications | Municipal and industrial wastewater, cooling water, process water, water in the chemical industry and paper making, generally water with solid fractions. |
Resistance to | Disinfectant, solids content (turbid types of water) |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, Teflon ring diaphragm, polymer electrolyte, separate temperature measurement for temperature compensation needed |
Order no. | |
---|---|
PHER 112 SE | 1001586 |
PH sensor PHER-DJ 112 SE
pH sensor with double diaphragm (double junction) optimised for use in contaminated water containing solids and for low conductivity of > 10 μS/cm at up to 80 °C/6 bar.
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- The large dirt-repellent Teflon® diaphragm prevents the reference system from becoming blocked up
- Long service life when solids are present
- High-viscosity electrolyte combined with a salt reservoir prevents the electrolyte from 'bleeding'
- Long service life without drifts when there is clear water with low conductivity
- Twist protection for the sensor cable connected. This means that the cables can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…80 °C |
Max. pressure | 6.0 bar |
Min. conductivity | 10 µS/cm |
Electrolyte | Gel containing potassium chloride with KCI reservoir |
Diaphragm | 2x PTFE ring diaphragm |
Sensor shaft | Glass |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | All DULCOMETER controllers |
Typical applications | Municipal and industrial wastewater, cooling water, process water, water in the chemical industry and paper making, generally water with solid fractions. |
Resistance to | Disinfectant, solids content (turbid types of water) |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, Teflon ring diaphragm, polymer electrolyte, separate temperature measurement for temperature compensation needed |
Installation length | Order no. | |
---|---|---|
PHER-DJ 112 SE | 120 ±3 mm | 1108991 |
pH Sensor PHEX 112 SE
pH sensor optimised for use with contaminated water with a high solids content at 6 bar/100 °C or 16 bar/25 °C
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Diaphragm and reference system optimised for extremely high solids content
- The solid electrolyte makes the diaphragm redundant and prevents the reference system from becoming blocked up
- Long service life when sludge is present due to lack of a diaphragm
- Long service life as the solid electrolyte prevents the electrolyte from 'bleeding'
- Stable reference system
- Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…100 °C |
Max. pressure | 16.0 bar (25 °C), 6.0 bar (100 °C) |
Min. conductivity | 500 µS/cm |
Electrolyte | Polymer containing potassium chloride (solid) |
Diaphragm | Circular gap diaphragm (solid electrolyte) |
Sensor shaft | Glass |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | all DULCOMETER controllers |
Typical applications | Wastewater, industrial water, process chemistry, emulsions, suspensions, protein-containing media, in general for water with a high solid fraction, not suitable for use in clear water. not suitable for media with oxidation agents. |
Resistance to | Solids content (turbid types of water), sludge, emulsions |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, no diaphragm, polymer electrolyte, separate temperature measurement for temperature compensation needed |
Installation length | Order no. | |
---|---|---|
PHEX 112 SE | 120 ±3 mm | 305096 |
PHEX 112 SE SLg225 | 225 ±3 mm | 150061 |
pH Sensor PHED 112 SE
pH sensor optimised for use with chemically contaminated but clear water at up to 80 °C/8 bar
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Diaphragm and reference system optimised for use in chemically contaminated but clear water
- Double junction: two coupled ceramic diaphragms protect the reference system
- Long service life when chemical pollutants are present
- Special construction permits a maximum pressure of 8 bar
- Twist protection for the sensor cable connected. This means that the cables can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…80 °C |
Max. pressure | 8.0 bar |
Min. conductivity | 150 µS/cm |
Electrolyte | Gel containing potassium chloride |
Diaphragm | Double junction |
Sensor shaft | Glass |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | all DULCOMETER controllers |
Typical applications | Chemically loaded wastewater, industrial water, cooling water. |
Resistance to | Disinfectants, water-soluble chemicals |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, double junction, gel electrolyte, separate temperature measurement for temperature compensation needed |
Order no. | |
---|---|
PHED 112 SE | 741036 |
pH Sensor PHEF 012 SE
pH sensor optimised for use with acidic water containing fluoride and abrasive water containing solids at up to 50 °C/7 bar
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Optimised pH glass for use in the presence of glass-corroding hydrofluoric acid (HF). HF is formed primarily in the presence of fluoride (F-) at a pH of < 4. Glass corrosion is promoted by a constant concentration of fluoride, a falling pH value and a rising temperature. The glass composition and structure of the PHEF type reduce the release of SiF4. Extended service life in the presence of fluoride (F-) at a pH of < 7
- The flat shape of the glass diaphragm and large ring diaphragm facilitate use in contaminated water, which also contains abrasive solids
pH-range | 0…12 |
Temperature | 0…50 °C |
Max. pressure | 7.0 bar |
Min. conductivity | 150 µS/cm |
Electrolyte | Gel containing potassium chloride |
Diaphragm | HDPE ring diaphragm, flat (Double Junction) |
Sensor shaft | Epoxy |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | all DULCOMETER controllers |
Typical applications | A significantly longer service life can be achieved compared with standard pH sensors in media containing hydrofluoric acid, e.g. wastewater from the semiconductor industry or electroplating applications and air scrubbers. |
Resistance to | Disinfectant, solids content (turbid types of water), hydrofluoric acid (HF), abrasive particles |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, PE ring diaphragm, HF-compatible flat glass diaphragm, gel electrolyte, separate temperature measurement for temperature compensation needed |
Order no. | |
---|---|
PHEF 012 SE | 1010511 |
pH sensor PHEF-DJ 112 SE
pH sensor with double diaphragm (double junction) optimised for acid water containing fluoride at up to 60 °C/8 barYour Benefits
- Electrochemical combination probe: pH and reference electrode integrated
- Precise and reliable pH measurement in water containing fluoride with low pH enables efficient processes and excellent process reliability
- A special pH glass and dirt-repellent double junction can extend the service life of the sensor and thereby minimise downtimes as well as maintenance requirements
- The combination of hydrofluoric acid-resistant glass and PTFE double junction makes the sensor suited to gas scrubbing applications where fluoride and dirt may be encountered at the same time
- Twist protection for the sensor cable connection ensures that the cable can remain connected during installation and removal of the sensor, reducing moisture on the plug-in contacts
pH-range | 1…12 |
Temperature | 0…60 °C |
Max. pressure | 6.0 bar |
Min. conductivity | 10 µS/cm |
Electrolyte | Gel containing potassium chloride with KCI reservoir |
Diaphragm | 2 x PTFE ring diaphragm, double junction |
Sensor shaft | Glass |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | all DULCOMETER controllers |
Typical applications | A significantly longer service life can be achieved compared with standard pH sensors in media containing hydrofluoric acid, e.g. wastewater from the semiconductor industry or electroplating applications and air scrubbers. Low conductivity water. |
Resistance to | Disinfectant, dirt |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, gel electrolyte, PTFE diaphragm, separate temperature measurement needed for temperature compensation |
Order no. | |
---|---|
PHEF-DJ 112 SE | 1114185 |
pH Sensor PHEN 112 SE
Refillable pH sensor optimised for use with chemically contaminated water at up to 80 °C/without excess pressure
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Renewable liquid electrolyte by continuous replenishment from an electrolyte bottle installed above the electrode
- 1 ceramic diaphragm made of special material and with an optimised size / with optimised pore diameter
- Twist protection for the sensor cable connected. This means that the cables can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Long service life in the presence of chemicals dissolved in the water, which could contaminate the reference system
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…80 °C |
Max. pressure | Operation at atmospheric pressure |
Min. conductivity | 150 µS/cm |
Electrolyte | KCL electrolyte, refillable |
Diaphragm | Ceramic |
Sensor shaft | Glass |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | all DULCOMETER controllers |
Typical applications | Wastewater, cooling water, chemically contaminated water. |
Resistance to | Disinfectant, only for clear types of water |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, liquid electrolyte, 1 ceramic diaphragm, separate temperature measurement for temperature compensation needed |
Order no. | |
---|---|
PHEN 112 SE | 305090 |
Delivered without PE storage tank and hose
Order no. | |
---|---|
PE storage tank with connectors and tube | 305058 |
For the PE storage tank, we recommend fitting approx. 0.5 - 1 m above the level of the measurement medium.
Capacity | Order no. | |
---|---|---|
KCl solution, 3 molar | 250 ml | 791440 |
KCl solution, 3 molar | 1,000 ml | 791441 |
pH Sensor PHEN 112 SE 3D
Refillable pH sensor optimised for use in contaminated water containing solids and water with a low conductivity of > 50 μS/cm at up to 80 °C/without overpressure
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Renewable liquid electrolyte through continuous replenishment from an electrolyte bottle installed above the electrode
- 3 ceramic diaphragms made of special material, with optimised size and optimised pore diameter
- Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Long service life in water with low conductivity of > 50 µS/cm and where solids are present
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…80 °C |
Max. pressure | Operation at atmospheric pressure |
Min. conductivity | 50 µS/cm |
Electrolyte | KCL electrolyte, refillable |
Diaphragm | 3 ceramic diaphragms |
Sensor shaft | Glass |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | All DULCOMETER controllers |
Typical applications | Wastewater, water with low conductivity, e.g. from reverse osmosis. |
Resistance to | Disinfectant, solids content (turbid types of water) |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, liquid electrolyte, 1 ceramic diaphragm, separate temperature measurement for temperature compensation needed |
Order no. | |
---|---|
PHEN 112 SE 3D | 150078 |
pH Sensor PHEK 112 S
pH sensor for use with manual measuring instruments, with plastic shaft, optimised for use in potable water treatment, swimming pools/hot tubs at up to 80 °C/3 bar
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Diaphragm and reference system optimised for use in swimming pools and for potable water
- Ceramic diaphragm with special material, optimised size and optimised pore diameter
- With plastic shaft to prevent glass breakage
- Mechanical protection of the glass diaphragm
- Long service life due to reduced diffusion ('bleeding') of the electrolyte
- Long service life due to the material, which is inert to aggressive disinfectants
- Stable reference system
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…60 °C |
Max. pressure | 3.0 bar |
Min. conductivity | 150 µS/cm |
Electrolyte | Gel containing potassium chloride |
Diaphragm | Ceramic |
Sensor shaft | Polycarbonate |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | none |
Electrical Connection | SN6 plug-in head |
Enclosure rating | IP 65 |
Process integration | Immersion by tripod or manually |
Controllers | all DULCOMETER controllers |
Typical applications | Hand-held measurement in swimming pools, potable water. |
Resistance to | Disinfectant |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, gel electrolyte, ceramic diaphragm, separate temperature measurement for temperature compensation needed |
Order no. | |
---|---|
PHEK 112 S | 305051 |
pH Sensor PHEK 112 SE
pH sensor with plastic shaft, optimised for use in potable water treatment, swimming pools/hot tubs at up to 60 °C/3 bar
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Diaphragm and reference system optimised for use in swimming pools and for potable water
- Ceramic diaphragm with special material, optimised size and optimised pore diameter
- With plastic shaft to prevent glass breakage
- Mechanical protection of the glass diaphragm
- Long service life due to reduced diffusion ('bleeding') of the electrolyte
- Long service life due to the material, which is inert to aggressive disinfectants
- Stable reference system
- Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…60 °C |
Max. pressure | 3.0 bar |
Min. conductivity | 150 µS/cm |
Electrolyte | Gel containing potassium chloride |
Diaphragm | Ceramic |
Sensor shaft | Polycarbonate |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | all DULCOMETER controllers |
Typical applications | Swimming pool, potable water, aquariums |
Resistance to | Disinfectant |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, gel electrolyte, ceramic diaphragm, separate temperature measurement for temperature compensation needed |
Order no. | |
---|---|
PHEK 112 SE | 1028457 |
pH Sensor PHEK-L 112 SE
pH sensor with plastic shaft, optimised for use in potable water treatment, swimming pools/hot tubs, horizontal installation possible, at up to 60 °C/3 bar
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- With plastic shaft to prevent glass breakage
- Horizontal (level) installation possible (90° angle) (usually limited to 0 - 75° angle)
- Diaphragm and reference system optimised for use in swimming pools and for potable water
- Ceramic diaphragm with special material and optimised size / optimised pore diameter
- Long service life due to reduced diffusion ('bleeding') of the electrolyte
- Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Long service life due to the material, which is inert to aggressive disinfectants
- Stable reference system
pH-range | 1…12 |
Temperature | 0…60 °C |
Max. pressure | 3.0 bar |
Min. conductivity | 150 µS/cm |
Electrolyte | Gel containing potassium chloride |
Diaphragm | Ceramic |
Sensor shaft | Polycarbonate |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical to horizontal |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | all DULCOMETER controllers |
Typical applications | Swimming pools, potable water, aquaria. Horizontal installation possible. |
Resistance to | Disinfectant |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, gel electrolyte, ceramic diaphragm, separate temperature measurement for temperature compensation needed |
Order no. | |
---|---|
PHEK-L 112 SE | 1034918 |
pH Sensor PHEPT 112 VE
pH sensor with integral temperature measurement, optimised for use with clear process water and changing process temperature of up to 80 °C/6 bar
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Diaphragm and reference system optimised for exacting process requirements
- Ceramic diaphragm with special material, optimised size and optimised pore diameter
- Long service life due to reduced diffusion ("bleeding") of the electrolyte
- Long service life due to the material, which is inert to aggressive chemicals
- Stable reference system for high pressure/temperature requirements
- Integrated Pt 100 temperature sensor for temperature compensation of the pH measurement in higher-order measuring instruments eliminates the need for an additional sensor housing and external temperature sensor
- VARIO Pin plug-in head with IP 67 specification
- Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…80 °C |
Max. pressure | 6.0 bar |
Min. conductivity | 150 µS/cm |
Electrolyte | Gel containing potassium chloride |
Diaphragm | Ceramic |
Sensor shaft | Glass |
Shaft diameter | 15 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | VARIO Pin plug-in head |
Enclosure rating | IP 67 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | All DULCOMETER controllers (with the exception of DCCa pH) |
Typical applications | Swimming pools during pressurisation for higher temperatures and pressures, potable and industrial water, electroplating, chemical industry, processes with a temperature change. |
Resistance to | Disinfectant |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, gel electrolyte, ceramic diaphragm, integrated temperature measurement for temperature compensation |
Order no. | |
---|---|
PHEPT 112 VE | 1004571 |
Downloads for DULCOTEST pH sensors
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.
Overview
Reliable online measurement of pH values – with DULCOTEST sensors
The online measurement and adjustment of pH values must be as accurate, fast and reliable as possible and provide good availability of the measured values, be it for the monitoring, control or regulation of chemical processes.
Our product line of DULCOTEST pH sensors provides a wide range of pH sensors for different measuring tasks.
Our pH sensors are manufactured to very strict quality controls (e.g. in accordance with RoHS guidelines). Routine steps are automated but critical steps are carried out manually under expert supervision. In this way we achieve the best reproducible quality and cost reduction.
Your benefits
- Precise and reliable pH measurement enables efficient processes and excellent process reliability
- The wide choice of sensor types with different constructions makes them reliable components in many applications
- A long service life is achieved through the use of the best quality materials for the glass and diaphragms, a stable reference system and optimised production. This minimises both downtime and maintenance
- With short storage times and fast delivery, your pH sensors can be up and running very quickly and you can make maximum use of their service life (all glass sensors start to age as soon as they leave production)
- Wide range of special versions for fitting length, cable length and plugs for made-to-measure connection to your process
- Unique label for OEM partners
Video
Application
Field of application
The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.
- Chemical processes
- Chemically contaminated water
- Swimming pool water, potable water
- Process water
- Cooling water, wastewater
- Seawater
- Suspensions, sludge, emulsions
- Exhaust air scrubber, semiconductor industry, electroplating
Technical Data
Technical Details
- Selection of sensor type according to the application
- The insertion angle must be > 15° from the horizontal (except with PHEK-L: horizontal to vertical)
- Maximum flow < 0.8 m/s
- With cable lengths > 10 m, use the 4-20 mA transducer type PHV1
- Calibration using quality buffer solutions
pH Sensor PHES 112 SE
pH sensor optimised for use in potable water treatment, swimming pools/hot tubs at up to 60 °C/3 bar
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Diaphragm and reference system optimised for use in swimming pools and for potable water
- Ceramic diaphragm with special material, optimised size and optimised pore diameter
- Long service life due to reduced diffusion ('bleeding') of the electrolyte
- Long service life due to the material, which is inert to aggressive disinfectants
- Stable reference system
- Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…60 °C |
Max. pressure | 3.0 bar |
Min. conductivity | 150 µS/cm |
Electrolyte | Gel containing potassium chloride |
Diaphragm | Ceramic |
Sensor shaft | Glass |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | All DULCOMETER controllers |
Typical applications | Swimming pools, whirlpools, potable water |
Resistance to | Disinfectant |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, gel electrolyte, ceramic diaphragm, separate temperature measurement for temperature compensation needed |
Installation length | Order no. | |
---|---|---|
PHES-112-SE SLg100 | 100 ±3 mm | 1051745 |
PHES 112 SE | 120 ±3 mm | 150702 |
PHES-112-SE SLg225 | 225 ±3 mm | 150092 |
pH Sensor PHES 112 SE 3D
pH sensor optimised for use in potable water treatment, swimming pools/hot tubs and at low electrolytic conductivities of up to 60 °C/3 bar
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Diaphragm and reference system optimised for use in swimming pools
- Ceramic diaphragm with special material, optimised size and optimised pore diameter
- Three ceramic diaphragms optimised for low electrolytic conductivities
- Long service life due to reduced diffusion ('bleeding') of the electrolyte
- Long service life due to the material, which is inert to aggressive disinfectants
- Stable reference system
- Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…60 °C |
Max. pressure | 3.0 bar |
Min. conductivity | 50 µS/cm |
Electrolyte | Gel containing potassium chloride |
Diaphragm | 3 ceramic diaphragms |
Sensor shaft | Glass |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | all DULCOMETER controllers |
Typical applications | Low conductivity water. |
Resistance to | Disinfectant |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, gel electrolyte, ceramic diaphragm, separate temperature measurement for temperature compensation needed |
Installation length | Order no. | |
---|---|---|
PHES 112 SE 3D | 120 ±3 mm | 1045759 |
pH Sensor PHEP 112 SE
pH sensor optimised for use with clear process water and conditions of up to 80 °C/6 bar
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Diaphragm and reference system optimised for exacting process requirements
- Ceramic diaphragm with special material, optimised size and optimised pore diameter
- Long service life due to reduced diffusion ('bleeding') of the electrolyte
- Long service life due to the material, which is inert to aggressive disinfectants
- Stable reference system for high pressure/temperature requirements
- Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…80 °C |
Max. pressure | 6.0 bar |
Min. conductivity | 150 µS/cm |
Electrolyte | Gel containing potassium chloride |
Diaphragm | Ceramic |
Sensor shaft | Glass |
Shaft diameter | 15 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | All DULCOMETER controllers |
Typical applications | Swimming pools during pressurisation for higher temperatures and pressures, potable and industrial water, electroplating, chemical industries. |
Resistance to | Disinfectant |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, gel electrolyte, ceramic diaphragm, separate temperature measurement for temperature compensation needed |
Installation length | Order no. | |
---|---|---|
PHEP 112 SE | 120 ±3 mm | 150041 |
PHEP 112 SE SLg100 | 100 ±3 mm | 150951 |
pH Sensor PHEP-H 314 SE
pH sensor optimised for use with clear process water, specifically for alkaline process solutions at high temperatures of up to 100 °C
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Diaphragm and reference system optimised for exacting process requirements
- Optimised pH-sensitive glass for high alkali content and high temperatures
- Long service life / excellent precision: Measurement at a high pH value of up to 14
- Long service life: at high temperatures of up to 100 °C
- Stable reference system for high pressure/temperature requirements
- Twist protection for the sensor cable connected. This means that the cables can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 3…14 |
Temperature | 0…100 °C |
Max. pressure | 6.0 bar (25 °C), 3.0 bar (100 °C) |
Min. conductivity | 150 µS/cm |
Electrolyte | Gel containing potassium chloride with KCI reservoir |
Diaphragm | Ceramic |
Sensor shaft | Glass |
Shaft diameter | 15 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | All DULCOMETER controllers |
Typical applications | Monitoring or control of chemical processes with neutral to highly-alkaline media and temperatures up to 100 °C. |
Resistance to | Disinfectant, high alkalinity |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, highly alkaline tempered glass, ceramic diaphragm, gel electrolyte, separate temperature measurement for temperature compensation needed |
Order no. | |
---|---|
PHEP-H 314 SE | 1024882 |
pH Sensor PHEI 112 SE
Reliable online measurement of pH values in industrial wastewater/water - with DULCOTEST sensorsYour Benefits
- Solid high-grade plastic housing with integrated process connection for direct installation in the process with ½" and ¾" NPT thread
- Large dirt-repellent Teflon diaphragm protects against unwanted blocking of the reference
- Double junction reference system for stability with chemically polluted water
- Large electrolyte reservoir for long service lives
pH-range | 1…12 |
Temperature | 0…80 °C |
Max. pressure | 6.0 bar |
Min. conductivity | 50 µS/cm |
Electrolyte | Gel containing potassium chloride with a large KCI reservoir of gel |
Diaphragm | 1 x PTFE ring diaphragm and 1x ceramic diaphragm |
Sensor shaft | Plastic |
Shaft diameter | 17 ±0.2 mm (below the ½” NPT thread), 22 ±0.2 mm (below the ¾” thread) |
Installation length | 20 ±0.2 mm (from the lower end of the ½” thread), 60 ±0.2 mm (from the lower end of the ¾” thread) |
Fitting position | Vertical up to +25° |
Thread | ½” and ¾” NPT thread |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | all DULCOMETER controllers |
Typical applications | Municipal and industrial wastewater Cooling water, process water, water in the chemical industry and paper making, generally for water with a solid matter fraction. |
Resistance to | Disinfectant, solids content (turbid water), water-soluble chemicals |
Measuring principle, technology | direct potentiometric measurement, 2 probes, double junction, gel electrolyte, large Teflon diaphragm, separate temperature measurement for temperature compensation needed |
Order no. | |
---|---|
PHEI 112 SE | 1076610 |
pH Sensor PHER 112 SE
pH sensor optimised for use in contaminated water containing solids and for low conductivity of > 50 μS/cm at up to 80 °C/6 bar
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- The large dirt-repellent Teflon® diaphragm prevents the reference system from becoming blocked up
- Long service life when solids are present
- High-viscosity electrolyte combined with a salt reservoir prevents the electrolyte from 'bleeding'
- Long service life without drifts when there is clear water with low conductivity
- Twist protection for the sensor cable connected. This means that the cables can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…80 °C |
Max. pressure | 6.0 bar |
Min. conductivity | 50 µS/cm |
Electrolyte | Gel containing potassium chloride with KCI reservoir |
Diaphragm | PTFE ring diaphragm |
Sensor shaft | Glass |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | All DULCOMETER controllers |
Typical applications | Municipal and industrial wastewater, cooling water, process water, water in the chemical industry and paper making, generally water with solid fractions. |
Resistance to | Disinfectant, solids content (turbid types of water) |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, Teflon ring diaphragm, polymer electrolyte, separate temperature measurement for temperature compensation needed |
Order no. | |
---|---|
PHER 112 SE | 1001586 |
PH sensor PHER-DJ 112 SE
pH sensor with double diaphragm (double junction) optimised for use in contaminated water containing solids and for low conductivity of > 10 μS/cm at up to 80 °C/6 bar.
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- The large dirt-repellent Teflon® diaphragm prevents the reference system from becoming blocked up
- Long service life when solids are present
- High-viscosity electrolyte combined with a salt reservoir prevents the electrolyte from 'bleeding'
- Long service life without drifts when there is clear water with low conductivity
- Twist protection for the sensor cable connected. This means that the cables can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…80 °C |
Max. pressure | 6.0 bar |
Min. conductivity | 10 µS/cm |
Electrolyte | Gel containing potassium chloride with KCI reservoir |
Diaphragm | 2x PTFE ring diaphragm |
Sensor shaft | Glass |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | All DULCOMETER controllers |
Typical applications | Municipal and industrial wastewater, cooling water, process water, water in the chemical industry and paper making, generally water with solid fractions. |
Resistance to | Disinfectant, solids content (turbid types of water) |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, Teflon ring diaphragm, polymer electrolyte, separate temperature measurement for temperature compensation needed |
Installation length | Order no. | |
---|---|---|
PHER-DJ 112 SE | 120 ±3 mm | 1108991 |
pH Sensor PHEX 112 SE
pH sensor optimised for use with contaminated water with a high solids content at 6 bar/100 °C or 16 bar/25 °C
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Diaphragm and reference system optimised for extremely high solids content
- The solid electrolyte makes the diaphragm redundant and prevents the reference system from becoming blocked up
- Long service life when sludge is present due to lack of a diaphragm
- Long service life as the solid electrolyte prevents the electrolyte from 'bleeding'
- Stable reference system
- Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…100 °C |
Max. pressure | 16.0 bar (25 °C), 6.0 bar (100 °C) |
Min. conductivity | 500 µS/cm |
Electrolyte | Polymer containing potassium chloride (solid) |
Diaphragm | Circular gap diaphragm (solid electrolyte) |
Sensor shaft | Glass |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | all DULCOMETER controllers |
Typical applications | Wastewater, industrial water, process chemistry, emulsions, suspensions, protein-containing media, in general for water with a high solid fraction, not suitable for use in clear water. not suitable for media with oxidation agents. |
Resistance to | Solids content (turbid types of water), sludge, emulsions |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, no diaphragm, polymer electrolyte, separate temperature measurement for temperature compensation needed |
Installation length | Order no. | |
---|---|---|
PHEX 112 SE | 120 ±3 mm | 305096 |
PHEX 112 SE SLg225 | 225 ±3 mm | 150061 |
pH Sensor PHED 112 SE
pH sensor optimised for use with chemically contaminated but clear water at up to 80 °C/8 bar
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Diaphragm and reference system optimised for use in chemically contaminated but clear water
- Double junction: two coupled ceramic diaphragms protect the reference system
- Long service life when chemical pollutants are present
- Special construction permits a maximum pressure of 8 bar
- Twist protection for the sensor cable connected. This means that the cables can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…80 °C |
Max. pressure | 8.0 bar |
Min. conductivity | 150 µS/cm |
Electrolyte | Gel containing potassium chloride |
Diaphragm | Double junction |
Sensor shaft | Glass |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | all DULCOMETER controllers |
Typical applications | Chemically loaded wastewater, industrial water, cooling water. |
Resistance to | Disinfectants, water-soluble chemicals |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, double junction, gel electrolyte, separate temperature measurement for temperature compensation needed |
Order no. | |
---|---|
PHED 112 SE | 741036 |
pH Sensor PHEF 012 SE
pH sensor optimised for use with acidic water containing fluoride and abrasive water containing solids at up to 50 °C/7 bar
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Optimised pH glass for use in the presence of glass-corroding hydrofluoric acid (HF). HF is formed primarily in the presence of fluoride (F-) at a pH of < 4. Glass corrosion is promoted by a constant concentration of fluoride, a falling pH value and a rising temperature. The glass composition and structure of the PHEF type reduce the release of SiF4. Extended service life in the presence of fluoride (F-) at a pH of < 7
- The flat shape of the glass diaphragm and large ring diaphragm facilitate use in contaminated water, which also contains abrasive solids
pH-range | 0…12 |
Temperature | 0…50 °C |
Max. pressure | 7.0 bar |
Min. conductivity | 150 µS/cm |
Electrolyte | Gel containing potassium chloride |
Diaphragm | HDPE ring diaphragm, flat (Double Junction) |
Sensor shaft | Epoxy |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | all DULCOMETER controllers |
Typical applications | A significantly longer service life can be achieved compared with standard pH sensors in media containing hydrofluoric acid, e.g. wastewater from the semiconductor industry or electroplating applications and air scrubbers. |
Resistance to | Disinfectant, solids content (turbid types of water), hydrofluoric acid (HF), abrasive particles |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, PE ring diaphragm, HF-compatible flat glass diaphragm, gel electrolyte, separate temperature measurement for temperature compensation needed |
Order no. | |
---|---|
PHEF 012 SE | 1010511 |
pH sensor PHEF-DJ 112 SE
pH sensor with double diaphragm (double junction) optimised for acid water containing fluoride at up to 60 °C/8 barYour Benefits
- Electrochemical combination probe: pH and reference electrode integrated
- Precise and reliable pH measurement in water containing fluoride with low pH enables efficient processes and excellent process reliability
- A special pH glass and dirt-repellent double junction can extend the service life of the sensor and thereby minimise downtimes as well as maintenance requirements
- The combination of hydrofluoric acid-resistant glass and PTFE double junction makes the sensor suited to gas scrubbing applications where fluoride and dirt may be encountered at the same time
- Twist protection for the sensor cable connection ensures that the cable can remain connected during installation and removal of the sensor, reducing moisture on the plug-in contacts
pH-range | 1…12 |
Temperature | 0…60 °C |
Max. pressure | 6.0 bar |
Min. conductivity | 10 µS/cm |
Electrolyte | Gel containing potassium chloride with KCI reservoir |
Diaphragm | 2 x PTFE ring diaphragm, double junction |
Sensor shaft | Glass |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | all DULCOMETER controllers |
Typical applications | A significantly longer service life can be achieved compared with standard pH sensors in media containing hydrofluoric acid, e.g. wastewater from the semiconductor industry or electroplating applications and air scrubbers. Low conductivity water. |
Resistance to | Disinfectant, dirt |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, gel electrolyte, PTFE diaphragm, separate temperature measurement needed for temperature compensation |
Order no. | |
---|---|
PHEF-DJ 112 SE | 1114185 |
pH Sensor PHEN 112 SE
Refillable pH sensor optimised for use with chemically contaminated water at up to 80 °C/without excess pressure
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Renewable liquid electrolyte by continuous replenishment from an electrolyte bottle installed above the electrode
- 1 ceramic diaphragm made of special material and with an optimised size / with optimised pore diameter
- Twist protection for the sensor cable connected. This means that the cables can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Long service life in the presence of chemicals dissolved in the water, which could contaminate the reference system
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…80 °C |
Max. pressure | Operation at atmospheric pressure |
Min. conductivity | 150 µS/cm |
Electrolyte | KCL electrolyte, refillable |
Diaphragm | Ceramic |
Sensor shaft | Glass |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | all DULCOMETER controllers |
Typical applications | Wastewater, cooling water, chemically contaminated water. |
Resistance to | Disinfectant, only for clear types of water |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, liquid electrolyte, 1 ceramic diaphragm, separate temperature measurement for temperature compensation needed |
Order no. | |
---|---|
PHEN 112 SE | 305090 |
Delivered without PE storage tank and hose
Order no. | |
---|---|
PE storage tank with connectors and tube | 305058 |
For the PE storage tank, we recommend fitting approx. 0.5 - 1 m above the level of the measurement medium.
Capacity | Order no. | |
---|---|---|
KCl solution, 3 molar | 250 ml | 791440 |
KCl solution, 3 molar | 1,000 ml | 791441 |
pH Sensor PHEN 112 SE 3D
Refillable pH sensor optimised for use in contaminated water containing solids and water with a low conductivity of > 50 μS/cm at up to 80 °C/without overpressure
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Renewable liquid electrolyte through continuous replenishment from an electrolyte bottle installed above the electrode
- 3 ceramic diaphragms made of special material, with optimised size and optimised pore diameter
- Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Long service life in water with low conductivity of > 50 µS/cm and where solids are present
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…80 °C |
Max. pressure | Operation at atmospheric pressure |
Min. conductivity | 50 µS/cm |
Electrolyte | KCL electrolyte, refillable |
Diaphragm | 3 ceramic diaphragms |
Sensor shaft | Glass |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | All DULCOMETER controllers |
Typical applications | Wastewater, water with low conductivity, e.g. from reverse osmosis. |
Resistance to | Disinfectant, solids content (turbid types of water) |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, liquid electrolyte, 1 ceramic diaphragm, separate temperature measurement for temperature compensation needed |
Order no. | |
---|---|
PHEN 112 SE 3D | 150078 |
pH Sensor PHEK 112 S
pH sensor for use with manual measuring instruments, with plastic shaft, optimised for use in potable water treatment, swimming pools/hot tubs at up to 80 °C/3 bar
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Diaphragm and reference system optimised for use in swimming pools and for potable water
- Ceramic diaphragm with special material, optimised size and optimised pore diameter
- With plastic shaft to prevent glass breakage
- Mechanical protection of the glass diaphragm
- Long service life due to reduced diffusion ('bleeding') of the electrolyte
- Long service life due to the material, which is inert to aggressive disinfectants
- Stable reference system
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…60 °C |
Max. pressure | 3.0 bar |
Min. conductivity | 150 µS/cm |
Electrolyte | Gel containing potassium chloride |
Diaphragm | Ceramic |
Sensor shaft | Polycarbonate |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | none |
Electrical Connection | SN6 plug-in head |
Enclosure rating | IP 65 |
Process integration | Immersion by tripod or manually |
Controllers | all DULCOMETER controllers |
Typical applications | Hand-held measurement in swimming pools, potable water. |
Resistance to | Disinfectant |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, gel electrolyte, ceramic diaphragm, separate temperature measurement for temperature compensation needed |
Order no. | |
---|---|
PHEK 112 S | 305051 |
pH Sensor PHEK 112 SE
pH sensor with plastic shaft, optimised for use in potable water treatment, swimming pools/hot tubs at up to 60 °C/3 bar
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Diaphragm and reference system optimised for use in swimming pools and for potable water
- Ceramic diaphragm with special material, optimised size and optimised pore diameter
- With plastic shaft to prevent glass breakage
- Mechanical protection of the glass diaphragm
- Long service life due to reduced diffusion ('bleeding') of the electrolyte
- Long service life due to the material, which is inert to aggressive disinfectants
- Stable reference system
- Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…60 °C |
Max. pressure | 3.0 bar |
Min. conductivity | 150 µS/cm |
Electrolyte | Gel containing potassium chloride |
Diaphragm | Ceramic |
Sensor shaft | Polycarbonate |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | all DULCOMETER controllers |
Typical applications | Swimming pool, potable water, aquariums |
Resistance to | Disinfectant |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, gel electrolyte, ceramic diaphragm, separate temperature measurement for temperature compensation needed |
Order no. | |
---|---|
PHEK 112 SE | 1028457 |
pH Sensor PHEK-L 112 SE
pH sensor with plastic shaft, optimised for use in potable water treatment, swimming pools/hot tubs, horizontal installation possible, at up to 60 °C/3 bar
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- With plastic shaft to prevent glass breakage
- Horizontal (level) installation possible (90° angle) (usually limited to 0 - 75° angle)
- Diaphragm and reference system optimised for use in swimming pools and for potable water
- Ceramic diaphragm with special material and optimised size / optimised pore diameter
- Long service life due to reduced diffusion ('bleeding') of the electrolyte
- Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Long service life due to the material, which is inert to aggressive disinfectants
- Stable reference system
pH-range | 1…12 |
Temperature | 0…60 °C |
Max. pressure | 3.0 bar |
Min. conductivity | 150 µS/cm |
Electrolyte | Gel containing potassium chloride |
Diaphragm | Ceramic |
Sensor shaft | Polycarbonate |
Shaft diameter | 12 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical to horizontal |
Thread | PG 13.5 |
Electrical Connection | SN6 plug-in head, rotatable with a ProMinent cable |
Enclosure rating | IP 65 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | all DULCOMETER controllers |
Typical applications | Swimming pools, potable water, aquaria. Horizontal installation possible. |
Resistance to | Disinfectant |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, gel electrolyte, ceramic diaphragm, separate temperature measurement for temperature compensation needed |
Order no. | |
---|---|
PHEK-L 112 SE | 1034918 |
pH Sensor PHEPT 112 VE
pH sensor with integral temperature measurement, optimised for use with clear process water and changing process temperature of up to 80 °C/6 bar
Your Benefits
- Electrochemical combination electrode: pH and reference electrode integrated
- Diaphragm and reference system optimised for exacting process requirements
- Ceramic diaphragm with special material, optimised size and optimised pore diameter
- Long service life due to reduced diffusion ("bleeding") of the electrolyte
- Long service life due to the material, which is inert to aggressive chemicals
- Stable reference system for high pressure/temperature requirements
- Integrated Pt 100 temperature sensor for temperature compensation of the pH measurement in higher-order measuring instruments eliminates the need for an additional sensor housing and external temperature sensor
- VARIO Pin plug-in head with IP 67 specification
- Twist protection for the sensor cable connected. This means that the cable can remain connected during installation and dismantling of the sensor, avoiding troublesome moisture on the connector contacts
- Lead-free glass for advanced and environmentally-friendly production, use and disposal (RoHS-compliant)
pH-range | 1…12 |
Temperature | 0…80 °C |
Max. pressure | 6.0 bar |
Min. conductivity | 150 µS/cm |
Electrolyte | Gel containing potassium chloride |
Diaphragm | Ceramic |
Sensor shaft | Glass |
Shaft diameter | 15 mm |
Installation length | 120 ±3 mm |
Fitting position | Vertical up to +25° |
Thread | PG 13.5 |
Electrical Connection | VARIO Pin plug-in head |
Enclosure rating | IP 67 |
Process integration | Bypass: open outlet or return of the sample water into the process line, inline: direct installation into the pipework; fixed or replaceable (replaceable fitting), tank, channel: Immersion in the immersion tube |
Controllers | All DULCOMETER controllers (with the exception of DCCa pH) |
Typical applications | Swimming pools during pressurisation for higher temperatures and pressures, potable and industrial water, electroplating, chemical industry, processes with a temperature change. |
Resistance to | Disinfectant |
Measuring principle, technology | Direct potentiometric measurement, 2 electrodes, gel electrolyte, ceramic diaphragm, integrated temperature measurement for temperature compensation |
Order no. | |
---|---|
PHEPT 112 VE | 1004571 |