Motor-Driven Metering Pump Sigma/ 1 (Basic type)
Capacity range 17 – 144 l/h, 12 – 4 bar
The Sigma/ 1 Basic is an extremely robust motor-driven metering pump with patented multi-layer safety diaphragm for excellent process reliability. It offers a wide range of power end designs, such as three-phase or 1-phase AC motors, also for use in areas at risk from explosion.
Product description
The robust pump for safe and reliable use
The Sigma/ 1 diaphragm metering pump, together with pumps of type Sigma/ 2 and Sigma/ 3, represents an integrated product range. They cover the capacity range from 17 to 1,030 l/h, with a consistent operating concept, control concept and spare parts management. A wide range of power end versions is available, including some for use in areas at risk from explosion.
Your benefits
Excellent process reliability:
- In the event of an accident, the feed chemical does not escape to the outside nor into the pump's power end, thanks to the patented multi-layer safety diaphragm with optical (optionally electric) signalling.
- Integrated relief valve protects the pump against overload and bleed option during the suction process ensures reliable operation.
Flexible adaptation to the process:
- The entire Sigma product range is available as standard in a 'Physiologically safe in respect of wetted materials' design.
- Metering pumps with electro-polished stainless steel metering head enable them to be used in hygienically challenging applications.
- Adaptation to specific installation situations, as the 'Liquid end on left' option can be selected as standard.
- Wide range of power end versions, also for use in ATEX areas and different flange designs for the use of customised motors.
Field of application
The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.
- Volume-proportional addition of chemicals in water treatment, e.g. sodium-calcium hypochlorite for the disinfection of potable water
- Addition of chemicals depending on the measured value, e.g. metering of acid and alkali for pH neutralisation in wastewater treatment
- Time-controlled addition of chemicals in the cooling water circuit
- Pulse-controlled metering in the bottling of different volumes e.g. glycerin filling of manometers
Technical Details
- Stroke length: 4 mm
- Stroke length adjustment range: 0 – 100%
- Stroke length adjustment: manually using self-locking rotary dial in 1% increments (optionally with actuator or control drive)
- With the right, constant conditions, correct installation and calibration, precision exceeds ±1 %, based on maximum stroke volume.
- Wetted materials: PVDF, stainless steel 1.4571/1.4404, special materials on request
- Patented multi-layer safety diaphragm with optical diaphragm rupture display (as option with diaphragm rupture warning system via a contact)
- Integrated hydraulic relief and bleed valve
- A wide range of power end versions is available: Three-phase standard AC motor, 1-phase AC motor, motors for use in areas at risk from explosion and different flange designs for use in customer-specific motors
- For areas at risk from explosion II 2G Ex h IIC T3 Gb X or II 2G Ex h IIC T4 Gb X (optional)
- IP 55 degree of protection
- Fibreglass-reinforced plastic housing
- Liquid end on left is available as standard
- For reasons of safety, provide suitable overflow devices during installation for all mechanically deflected diaphragm metering pumps
Technical Data
Type | Capacity at max. back pressure with 1500 rpm motor at 50 Hz | Pump capacity at max. back pressure with 1800 rpm motor at 60 Hz | Suction lift | Perm. pre-pressure suction side | Connector Suction/Discharge Side | Shipping weight | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
Max. stroke rate | Max. stroke rate | ||||||||||
S1Ba | l/h | bar | ml/stroke | Strokes/min | l/h / gph (US) | psi | Strokes/min | m WC | bar | G-DN | kg |
12017 PVT | 17 | 10 | 3.8 | 73 | 20.4/5.3 | 145 | 88 | 7 | 1 | 3/4–10 | 9 |
12017 SST | 17 | 12 | 3.8 | 73 | 20.4/5.3 | 145 | 88 | 7 | 1 | 3/4–10 | 12 |
12035 PVT | 35 | 10 | 4.0 | 143 | 42.0/11.0 | 145 | 172 | 7 | 1 | 3/4–10 | 9 |
12035 SST | 35 | 12 | 4.0 | 143 | 42.0/11.0 | 174 | 172 | 7 | 1 | 3/4–10 | 12 |
10050 PVT | 50 | 10 | 4.0 | 205 | 60.0/15.8 | 145 | 246 | 7 | 1 | 3/4–10 | 9 |
10050 SST | 50 | 10 | 4.0 | 205 | 60.0/15.8 | 145 | 246 | 7 | 1 | 3/4–10 | 12 |
10022 PVT | 22 | 10 | 5.0 | 73 | 26.4/6.9 | 145 | 88 | 6 | 1 | 3/4–10 | 9 |
10022 SST | 22 | 10 | 5.0 | 73 | 26.4/6.9 | 145 | 88 | 6 | 1 | 3/4–10 | 12 |
10044 PVT | 44 | 10 | 5.1 | 143 | 52.8/13.9 | 145 | 172 | 6 | 1 | 3/4–10 | 9 |
10044 SST | 44 | 10 | 5.1 | 143 | 52.8/13.9 | 145 | 172 | 6 | 1 | 3/4–10 | 12 |
07065 PVT | 65 | 7 | 5.2 | 205 | 78.0/20.6 | 102 | 246 | 6 | 1 | 3/4–10 | 9 |
07065 SST | 65 | 7 | 5.2 | 205 | 78.0/20.6 | 102 | 246 | 6 | 1 | 3/4–10 | 12 |
07042 PVT | 42 | 7 | 9.5 | 73 | 50.4/13.3 | 102 | 88 | 3 | 1 | 1–15 | 10 |
07042 SST | 42 | 7 | 9.5 | 73 | 50.4/13.3 | 102 | 88 | 3 | 1 | 1–15 | 14 |
04084 PVT | 84 | 4 | 9.7 | 143 | 100.8/26.6 | 58 | 172 | 3 | 1 | 1–15 | 10 |
04084 SST | 84 | 4 | 9.7 | 143 | 100.8/26.6 | 58 | 172 | 3 | 1 | 1–15 | 14 |
04120 PVT | 120 | 4 | 9.7 | 205 | 144.0/38.0 | 58 | 246 | 3 | 1 | 1–15 | 10 |
04120 SST | 120 | 4 | 9.7 | 205 | 144.0/38.0 | 58 | 246 | 3 | 1 | 1–15 | 14 |
Performance data for TTT, see type PVT
Integrated relief valve, connector for DN 10 pressure hose sleeve
Materials in Contact with the Medium
Identity code of material | Dosing head | Connection on suction/discharge side | Seals/ball seat | Balls | Integral relief valve |
---|---|---|---|---|---|
* Specifically for areas at risk from explosion | |||||
PVT | PVDF | PVDF | PTFE/PTFE | Ceramic | PVDF/FKM or EPDM |
SST | Stainless steel 1.4404 | Stainless steel 1.4581 | PTFE/PTFE | Stainless steel 1.4404 | Stainless steel/FKM or EPDM |
TTT * | PTFE + 25% carbon | Carbon-filled PTFE | PTFE/PTFE | Ceramic | - |
PVF | PVDF | PVDF | PTFE/PTFE | Ceramic | PVDF/FKM or EPDM |
SSF | Stainless steel 1.4404 | Stainless steel 1.4581 | PTFE/PTFE | Stainless steel 1.4404 | Stainless steel/FKM or EPDM |
SSG | Stainless steel 1.4404 | Stainless steel 1.4581 | PTFE/stainless steel 1.4404 | Stainless steel 1.4404 | - |
SSH | Stainless steel 1.4435 | Stainless steel 1.4435 | EPDM or FKM/stainless steel 1.4435 | Ceramic | - |
Motor Data
Identity code specification | Power supply | Δ/Y | Remarks | ||
S | 3-phase, IP 55* | 230 V/400 V | 50 Hz | 0.09 kW | |
T | 3-phase, IP 55* | 230 V/400 V 265 V/460 V | 50 Hz 60 Hz | 0.09 kW 0.09 kW | With PTC, speed control range 1:5 |
R | 3-phase, IP 55* | 230 V/400 V | 50 Hz | 0.09 kW | With PTC, speed control range 1:20 with external fan (1-phase 230 V; 50/60 Hz, 20 W) |
M | 1-phase AC, IP 55 | 230 V ± 5 % | 50 Hz | 0.12 kW | |
N | 1-phase AC, IP 55 | 120 V ± 5 % | 60 Hz | 0.12 kW | |
L1 | 3-phase, II2GExellT3 | 220 – 240 V/380 – 420 V | 50 Hz | 0.12 kW | |
L2 | 3-phase, II2GExdllCT4 | 220 – 240 V/380 – 420 V | 50 Hz | 0.18 kW | With PTC, speed control range 1:5 |
Motor data sheets can be requested for more information. Versions 265/460V - 60Hz, special motors or special motor flanges are available on request.
Motors less than 0.75 kW and motors designed for speed-controllable operation are not subject to the IE3 standard in compliance with the Ecodesign Directive 2009/125/EC.
Information for use in areas at risk from explosion
Only use pumps with the appropriate labelling in line with the ATEX Directive 2014/34/EC in premises at risk from explosion. Ensure that the explosion group, category and degree of protection specified on the label correspond to or are superior to the conditions prevalent in the intended application.
Downloads for Motor-Driven Metering Pump Sigma/ 1 (Basic type)
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.
Overview
The robust pump for safe and reliable use
The Sigma/ 1 diaphragm metering pump, together with pumps of type Sigma/ 2 and Sigma/ 3, represents an integrated product range. They cover the capacity range from 17 to 1,030 l/h, with a consistent operating concept, control concept and spare parts management. A wide range of power end versions is available, including some for use in areas at risk from explosion.
Your benefits
Excellent process reliability:
- In the event of an accident, the feed chemical does not escape to the outside nor into the pump's power end, thanks to the patented multi-layer safety diaphragm with optical (optionally electric) signalling.
- Integrated relief valve protects the pump against overload and bleed option during the suction process ensures reliable operation.
Flexible adaptation to the process:
- The entire Sigma product range is available as standard in a 'Physiologically safe in respect of wetted materials' design.
- Metering pumps with electro-polished stainless steel metering head enable them to be used in hygienically challenging applications.
- Adaptation to specific installation situations, as the 'Liquid end on left' option can be selected as standard.
- Wide range of power end versions, also for use in ATEX areas and different flange designs for the use of customised motors.
Application
Field of application
The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.
- Volume-proportional addition of chemicals in water treatment, e.g. sodium-calcium hypochlorite for the disinfection of potable water
- Addition of chemicals depending on the measured value, e.g. metering of acid and alkali for pH neutralisation in wastewater treatment
- Time-controlled addition of chemicals in the cooling water circuit
- Pulse-controlled metering in the bottling of different volumes e.g. glycerin filling of manometers
Technical Data
Technical Details
- Stroke length: 4 mm
- Stroke length adjustment range: 0 – 100%
- Stroke length adjustment: manually using self-locking rotary dial in 1% increments (optionally with actuator or control drive)
- With the right, constant conditions, correct installation and calibration, precision exceeds ±1 %, based on maximum stroke volume.
- Wetted materials: PVDF, stainless steel 1.4571/1.4404, special materials on request
- Patented multi-layer safety diaphragm with optical diaphragm rupture display (as option with diaphragm rupture warning system via a contact)
- Integrated hydraulic relief and bleed valve
- A wide range of power end versions is available: Three-phase standard AC motor, 1-phase AC motor, motors for use in areas at risk from explosion and different flange designs for use in customer-specific motors
- For areas at risk from explosion II 2G Ex h IIC T3 Gb X or II 2G Ex h IIC T4 Gb X (optional)
- IP 55 degree of protection
- Fibreglass-reinforced plastic housing
- Liquid end on left is available as standard
- For reasons of safety, provide suitable overflow devices during installation for all mechanically deflected diaphragm metering pumps
Technical Data
Type | Capacity at max. back pressure with 1500 rpm motor at 50 Hz | Pump capacity at max. back pressure with 1800 rpm motor at 60 Hz | Suction lift | Perm. pre-pressure suction side | Connector Suction/Discharge Side | Shipping weight | |||||
---|---|---|---|---|---|---|---|---|---|---|---|
Max. stroke rate | Max. stroke rate | ||||||||||
S1Ba | l/h | bar | ml/stroke | Strokes/min | l/h / gph (US) | psi | Strokes/min | m WC | bar | G-DN | kg |
12017 PVT | 17 | 10 | 3.8 | 73 | 20.4/5.3 | 145 | 88 | 7 | 1 | 3/4–10 | 9 |
12017 SST | 17 | 12 | 3.8 | 73 | 20.4/5.3 | 145 | 88 | 7 | 1 | 3/4–10 | 12 |
12035 PVT | 35 | 10 | 4.0 | 143 | 42.0/11.0 | 145 | 172 | 7 | 1 | 3/4–10 | 9 |
12035 SST | 35 | 12 | 4.0 | 143 | 42.0/11.0 | 174 | 172 | 7 | 1 | 3/4–10 | 12 |
10050 PVT | 50 | 10 | 4.0 | 205 | 60.0/15.8 | 145 | 246 | 7 | 1 | 3/4–10 | 9 |
10050 SST | 50 | 10 | 4.0 | 205 | 60.0/15.8 | 145 | 246 | 7 | 1 | 3/4–10 | 12 |
10022 PVT | 22 | 10 | 5.0 | 73 | 26.4/6.9 | 145 | 88 | 6 | 1 | 3/4–10 | 9 |
10022 SST | 22 | 10 | 5.0 | 73 | 26.4/6.9 | 145 | 88 | 6 | 1 | 3/4–10 | 12 |
10044 PVT | 44 | 10 | 5.1 | 143 | 52.8/13.9 | 145 | 172 | 6 | 1 | 3/4–10 | 9 |
10044 SST | 44 | 10 | 5.1 | 143 | 52.8/13.9 | 145 | 172 | 6 | 1 | 3/4–10 | 12 |
07065 PVT | 65 | 7 | 5.2 | 205 | 78.0/20.6 | 102 | 246 | 6 | 1 | 3/4–10 | 9 |
07065 SST | 65 | 7 | 5.2 | 205 | 78.0/20.6 | 102 | 246 | 6 | 1 | 3/4–10 | 12 |
07042 PVT | 42 | 7 | 9.5 | 73 | 50.4/13.3 | 102 | 88 | 3 | 1 | 1–15 | 10 |
07042 SST | 42 | 7 | 9.5 | 73 | 50.4/13.3 | 102 | 88 | 3 | 1 | 1–15 | 14 |
04084 PVT | 84 | 4 | 9.7 | 143 | 100.8/26.6 | 58 | 172 | 3 | 1 | 1–15 | 10 |
04084 SST | 84 | 4 | 9.7 | 143 | 100.8/26.6 | 58 | 172 | 3 | 1 | 1–15 | 14 |
04120 PVT | 120 | 4 | 9.7 | 205 | 144.0/38.0 | 58 | 246 | 3 | 1 | 1–15 | 10 |
04120 SST | 120 | 4 | 9.7 | 205 | 144.0/38.0 | 58 | 246 | 3 | 1 | 1–15 | 14 |
Performance data for TTT, see type PVT
Integrated relief valve, connector for DN 10 pressure hose sleeve
Materials in Contact with the Medium
Identity code of material | Dosing head | Connection on suction/discharge side | Seals/ball seat | Balls | Integral relief valve |
---|---|---|---|---|---|
* Specifically for areas at risk from explosion | |||||
PVT | PVDF | PVDF | PTFE/PTFE | Ceramic | PVDF/FKM or EPDM |
SST | Stainless steel 1.4404 | Stainless steel 1.4581 | PTFE/PTFE | Stainless steel 1.4404 | Stainless steel/FKM or EPDM |
TTT * | PTFE + 25% carbon | Carbon-filled PTFE | PTFE/PTFE | Ceramic | - |
PVF | PVDF | PVDF | PTFE/PTFE | Ceramic | PVDF/FKM or EPDM |
SSF | Stainless steel 1.4404 | Stainless steel 1.4581 | PTFE/PTFE | Stainless steel 1.4404 | Stainless steel/FKM or EPDM |
SSG | Stainless steel 1.4404 | Stainless steel 1.4581 | PTFE/stainless steel 1.4404 | Stainless steel 1.4404 | - |
SSH | Stainless steel 1.4435 | Stainless steel 1.4435 | EPDM or FKM/stainless steel 1.4435 | Ceramic | - |
Motor Data
Identity code specification | Power supply | Δ/Y | Remarks | ||
S | 3-phase, IP 55* | 230 V/400 V | 50 Hz | 0.09 kW | |
T | 3-phase, IP 55* | 230 V/400 V 265 V/460 V | 50 Hz 60 Hz | 0.09 kW 0.09 kW | With PTC, speed control range 1:5 |
R | 3-phase, IP 55* | 230 V/400 V | 50 Hz | 0.09 kW | With PTC, speed control range 1:20 with external fan (1-phase 230 V; 50/60 Hz, 20 W) |
M | 1-phase AC, IP 55 | 230 V ± 5 % | 50 Hz | 0.12 kW | |
N | 1-phase AC, IP 55 | 120 V ± 5 % | 60 Hz | 0.12 kW | |
L1 | 3-phase, II2GExellT3 | 220 – 240 V/380 – 420 V | 50 Hz | 0.12 kW | |
L2 | 3-phase, II2GExdllCT4 | 220 – 240 V/380 – 420 V | 50 Hz | 0.18 kW | With PTC, speed control range 1:5 |
Motor data sheets can be requested for more information. Versions 265/460V - 60Hz, special motors or special motor flanges are available on request.
Motors less than 0.75 kW and motors designed for speed-controllable operation are not subject to the IE3 standard in compliance with the Ecodesign Directive 2009/125/EC.
Information for use in areas at risk from explosion
Only use pumps with the appropriate labelling in line with the ATEX Directive 2014/34/EC in premises at risk from explosion. Ensure that the explosion group, category and degree of protection specified on the label correspond to or are superior to the conditions prevalent in the intended application.
Downloads
Downloads for Motor-Driven Metering Pump Sigma/ 1 (Basic type)
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.
Contact us
Mr. Vikalp Tripathi
Managing Director, Heidelberg ProMinent Fluid Controls India Pvt. Ltd.