Back Pressure Valves/Relief Valves for Motor-Driven Metering Pumps
Back pressure valves are used to generate a constant back pressure and achieve precise metering in systems with a free outlet. They are also used in conjunction with pulsation dampers to provide low-pulsation metering.
Product description
Accurately metered
Back pressure valves for motor-driven metering pumps are designed for different applications. Please refer to the relevant notes for the different designs.
Relief valves are used in the bypass to protect pumps, pipes and fittings from overpressure in the event of incorrect operation or blockages. In the event of a malfunction, the pump pumps back into the storage tank.
The benefits for you
- Protects against overpressure
- Priming aid
- Relieves the pressure line
- Increases dosing precision
Back Pressure Valve/Relief Valve Type DHV-U
Universal back pressure valves of the DHV-U product range are back pressure-free piston diaphragm valves with an internal flow. They are used to generate a constant back pressure and also as relief valves. They can be installed at any location in the pipework system.
Back pressure valves are used to generate a constant back pressure for precise pumping and to protect against over-metering where there is a free outlet, fluctuating back pressure or priming pressure on the suction side. They are also used in conjunction with pulsation dampers to generate low-pulsation metering.
Relief valves are used to protect pumps, pipes and fittings from overpressure, in the event of incorrect operation or blockages in the bypass. In the event of a malfunction, the pump pumps around the circuit or back into the supply tank.
Important: Back pressure valves cannot be used as absolutely leak-tight shut-off devices. Take appropriate safety precautions when handling hazardous media. Relief valves are not safety valves by their definition as per DIN EN ISO 4126-1.
Important: Take appropriate safety measures (e.g. flushing after possible response) when using as relief valves in conjunction with viscous media (e.g. lime milk).
Adjustable pressure 0.5 - 10 bar
Application of PPE/PPB/PCE/PCB
20 °C - max. operating pressure 10 bar
Application of PVT/SST
30 °C - max. operating pressure 10 bar
Version | Nominal diameter | Dim. G | Order no. |
---|---|---|---|
PPB | DN 10 | 3/4 | 1038133 |
PPE | DN 10 | 3/4 | 1037285 |
PCB Version | DN 10 | 3/4 | 1037765 |
PVT | DN 10 | 3/4 | 1037767 |
PCE | DN 10 | 3/4 | 1038144 |
SST | DN 10 | 3/4 | 1043194 |
PPB | DN 15 | 1 | 1038145 |
PPE | DN 15 | 1 | 1036816 |
PCB | DN 15 | 1 | 1037764 |
PVT | DN 15 | 1 | 1037766 |
PCE | DN 15 | 1 | 1038146 |
SST | DN 15 | 1 | 1043193 |
PPB | DN 20 | 1 1/4 | 1038147 |
PPE | DN 20 | 1 1/4 | 1037284 |
PCB | DN 20 | 1 1/4 | 1037775 |
PVT | DN 20 | 1 1/4 | 1037777 |
PCE | DN 20 | 1 1/4 | 1038148 |
SST | DN 20 | 1 1/4 | 1043192 |
PPB | DN 25 | 1 1/2 | 1038149 |
PPE | DN 25 | 1 1/2 | 1036633 |
PCB | DN 25 | 1 1/2 | 1037774 |
PVT | DN 25 | 1 1/2 | 1037776 |
PCE | DN 25 | 1 1/2 | 1038150 |
SST | DN 25 | 1 1/2 | 1043191 |
PPE | DN 32 | 2 | 1051517 |
PVT | DN 32 | 2 | 1051503 |
PCE | DN 32 | 2 | 1051514 |
SST | DN 32 | 2 | 1051516 |
PCB | DN 32 | 2 | 1051520 |
PPB | DN 32 | 2 | 1051522 |
PPE | DN 40 | 2 1/4 | 1051518 |
PCE | DN 40 | 2 1/4 | 1051501 |
PVT | DN 40 | 2 1/4 | 1051502 |
SST | DN 40 | 2 1/4 | 1051515 |
PCB | DN 40 | 2 1/4 | 1051519 |
PPB | DN 40 | 2 1/4 | 1051521 |
Materials used
Version | Housing/Connectors | Plungers | Plunger Seal | Seal/Connectors |
---|---|---|---|---|
* Cover ring made from PTFE/FKM | ||||
PPE | PP | PVDF | EPDM | EPDM |
PPB | PP | PVDF | FKM | FKM |
PCE | PVC | PVDF | EPDM | EPDM |
PCB | PVC | PVDF | FKM | FKM |
PVT | PVDF | PVDF | PTFE * | FKM |
SST | 1.4404 | PTFE | PTFE * | PTFE |
Dimensions of DHV-U (PP, PVC, PVDF design)
DN | G | H | L | h | D | m | B |
---|---|---|---|---|---|---|---|
mm | mm | mm | mm | mm | |||
10 | 3/4 | 144 | 118 | 24 | 79 | M6 | 40 |
15 | 1 | 144 | 118 | 24 | 79 | M6 | 40 |
20 | 1 1/4 | 196 | 150 | 37 | 99 | M6 | 46 |
25 | 1 1/2 | 196 | 150 | 37 | 99 | M6 | 46 |
32 | 2 | 252 | 200 | 54 | 139.5 | M8 | 65 |
40 | 2 1/4 | 252 | 200 | 54 | 139.5 | M8 | 65 |
Dimensions of DHV-U (SS version)
DN | G | H* | L | h | D | m | B |
---|---|---|---|---|---|---|---|
mm | mm | mm | mm | mm | |||
* Approximate values | |||||||
10 | 3/4 | 144 | 118 | 20 | 79 | M6 | 40 |
15 | 1 | 144 | 118 | 20 | 79 | M6 | 40 |
20 | 1 1/4 | 196 | 150 | 30 | 99 | M6 | 46 |
25 | 1 1/2 | 196 | 150 | 30 | 99 | M6 | 46 |
32 | 2 | 252 | 200 | 37 | 139.5 | M8 | 65 |
40 | 2 1/4 | 252 | 200 | 37 | 139.5 | M8 | 65 |
Back Pressure Valve/Relief Valve Type DHV-U in physiologically safe design (FDA)
Back pressure valves for motor-driven metering pumps are designed for different applications. Please refer to the relevant notes for the different designs.
Relief valves are used in the bypass to protect pumps, pipes and fittings from overpressure in the event of incorrect operation or blockages. In the event of a malfunction, the pump pumps back into the storage tank.
Adjustable pressure 0.5 - 10 bar
Application of PPE/PPB/PCE/PCB
20 °C - max. operating pressure 10 bar
Application of PVT/SST
30 °C - max. operating pressure 10 bar
Version | Nominal diameter | Dim. G | Order no. |
---|---|---|---|
PPE | DN 10 | 3/4 | 1076578 |
SST | DN 10 | 3/4 | 1076532 |
PVT | DN 10 | 3/4 | 1076579 |
PPE | DN 15 | 1 | 1076580 |
SST | DN 15 | 1 | 1076531 |
PVT | DN 15 | 1 | 1076581 |
PVT | DN 20 | 1 1/4 | 1076583 |
PPE | DN 20 | 1 1/4 | 1076582 |
SST | DN 20 | 1 1/4 | 1076597 |
PPE | DN 25 | 1 1/2 | 1076585 |
SST | DN 25 | 1 1/2 | 1076584 |
PVT | DN 25 | 1 1/2 | 1076586 |
PVT | DN 32 | 2 | 1076588 |
PPE | DN 32 | 2 | 1076587 |
SST | DN 32 | 2 | 1076589 |
PPE | DN 40 | 2 1/4 | 1076590 |
PVT | DN 40 | 2 1/4 | 1076591 |
SST | DN 40 | 2 1/4 | 1076592 |
Materials used
Version | Housing/Connectors | Plungers | Plunger Seal | Seal/Connectors |
---|---|---|---|---|
* Cover ring made from PTFE/FKM | ||||
PPE | PP | PVDF | EPDM | EPDM |
PVT | PVDF | PVDF | PTFE * | FKM |
SST | 1.4404 | PTFE | PTFE * | PTFE |
All wetted materials in the 'Physiologically safe (FDA) in respect of wetted materials' design comply with the following FDA guidelines:
Material | Guideline |
PTFE | 21CFR177.1510 |
PVDF | 21CFR177.2510 |
PP | 21CFR177.1520 |
EPDM/FKM | 21CFR177.2600 |
We are happy to supply back pressure valves and relief valves DHV-U/DHV-UR in stainless steel and wetted EC 1935/2004 on request.
Relief valve type DHV-UR
The universal relief valves type DHV-UR, like all valves of the DHV-U product range, are infinitely adjustable piston diaphragm valves with internal flow. In the event of impermissible overpressure, the internal piston diaphragm opens the second outlet line, the relief outlet. It can be installed at any location in the pipework system. Very low pressure losses with a closed relief valve due to virtually free pipe cross-section Simple spare parts management, the wear parts (pressure spring, diaphragms, plunger seal, seal connection set) correspond to the DHV-U range of valves.
The benefits of the new relief valves DHV-UR include simpler assembly due to the saving of installation material/connection parts etc. and a reduction of adhesion points. The new installation method permits a slimmer design of metering stations.
Relief valves for fitting directly into the discharge line of the motor-driven metering pump with the functions:
- Installation at any location in the pipework system.
- Very low pressure losses with a closed relief valve due to virtually free pipe cross-section
Adjustable pressure
0.5 – 10 bar
Application of PP and PVC (PPE/PPB/PCE/PCB)
20 °C - maximum operating pressure 10 bar
Application of PVDF and stainless steel (PVT/SST)
30 °C - maximum operating pressure 10 bar
The benefits for you:
- Simpler installation due to saving of installation material/connecting parts
- Reduced adhesion points.
- Slimmer construction type of metering stations.
- Simple spare parts management, wear parts conform to the DHV-U valve product range.
Version | Nominal diameter | Dim. G | Order no. |
---|---|---|---|
PVT | DN 10 | 3/4 | 1061365 |
PPE | DN 10 | 3/4 | 1061337 |
PCE | DN 10 | 3/4 | 1061339 |
PPB | DN 10 | 3/4 | 1061341 |
PCB | DN 10 | 3/4 | 1061343 |
SST | DN 10 | 3/4 | 1061550 |
PCB | DN 15 | 1 | 1061342 |
PPE | DN 15 | 1 | 1061336 |
PCE | DN 15 | 1 | 1061338 |
PPB | DN 15 | 1 | 1061340 |
PVT | DN 15 | 1 | 1061364 |
SST | DN 15 | 1 | 1061551 |
PCE | DN 20 | 1 1/4 | 1061369 |
PPE | DN 20 | 1 1/4 | 1061367 |
PPB | DN 20 | 1 1/4 | 1061371 |
PCB | DN 20 | 1 1/4 | 1061373 |
PVT | DN 20 | 1 1/4 | 1061375 |
SST | DN 20 | 1 1/4 | 1061569 |
PCE | DN 25 | 1 1/2 | 1061368 |
PPE | DN 25 | 1 1/2 | 1061366 |
PPB | DN 25 | 1 1/2 | 1061370 |
PCB | DN 25 | 1 1/2 | 1061372 |
PVT | DN 25 | 1 1/2 | 1061374 |
SST | DN 25 | 1 1/2 | 1061570 |
Materials used
Version | Housing/Connectors | Plungers | Plunger Seal | Seal/Connectors |
---|---|---|---|---|
* Cover ring made from PTFE/FKM | ||||
PPE | PP | PVDF | EPDM | EPDM |
PPB | PP | PVDF | FKM | FKM |
PCE | PVC | PVDF | EPDM | EPDM |
PCB | PVC | PVDF | FKM | FKM |
PVT | PVDF | PVDF | PTFE * | FKM |
SST | 1.4404 | 1.4404 | PTFE * | PTFE |
Dimensions of DHV-UR (PP, PVC, PVDF design)
DN | G | H* | L | h | D | m | B |
---|---|---|---|---|---|---|---|
mm | mm | mm | mm | mm | |||
* Approximate values | |||||||
10 | 3/4 | 144 | 118 | 24 | 79 | M6 | 35 |
15 | 1 | 144 | 118 | 24 | 79 | M6 | 35 |
20 | 1 1/4 | 196 | 150 | 37 | 99 | M6 | 46 |
25 | 1 1/2 | 196 | 150 | 37 | 99 | M6 | 46 |
Dimensions of DHV-UR (SS design)
DN | G | H* | L | h | D | m | B |
---|---|---|---|---|---|---|---|
mm | mm | mm | mm | mm | |||
* Approximate values | |||||||
10 | 3/4 | 144 | 118 | 24 | 79 | M6 | 35 |
15 | 1 | 144 | 118 | 24 | 79 | M6 | 35 |
20 | 1 1/4 | 196 | 150 | 37 | 99 | M6 | 46 |
25 | 1 1/2 | 196 | 150 | 37 | 99 | M6 | 46 |
Relief valve type DHV-UR, FDA design
Back pressure valves for motor-driven metering pumps are designed for different applications. Please refer to the relevant notes for the different designs.
Relief valves are used in the bypass to protect pumps, pipes and fittings from overpressure in the event of incorrect operation or blockages. In the event of a malfunction, the pump pumps back into the storage tank.
Adjustable pressure 0.5 - 10 bar
Application of PPE/PPB/PCE/PCB:
20 °C - max. operating pressure 10 bar
Application of PVT/SST:
30 °C - max. operating pressure 10 bar
Version | Nominal diameter | Dim. G | Order no. |
---|---|---|---|
PVT | DN 10 | 3/4 | 1075830 |
PPE | DN 10 | 3/4 | 1075828 |
SST | DN 10 | 3/4 | 1075847 |
PVT | DN 15 | 1 | 1075829 |
PPE | DN 15 | 1 | 1075827 |
SST | DN 15 | 1 | 1075846 |
PPE | DN 20 | 1 1/4 | 1075833 |
PVT | DN 20 | 1 1/4 | 1075845 |
SST | DN 20 | 1 1/4 | 1075849 |
PVT | DN 25 | 1 1/2 | 1075844 |
PPE | DN 25 | 1 1/2 | 1075832 |
SST | DN 25 | 1 1/2 | 1075848 |
Materials used
Version | Housing/Connectors | Plungers | Plunger Seal | Seal/Connectors |
---|---|---|---|---|
* Cover ring made from PTFE/FKM | ||||
PPE | PP | PVDF | EPDM | EPDM |
PVT | PVDF | PVDF | PTFE * | FKM |
SST | 1.4404 | PTFE | PTFE * | PTFE |
All wetted materials in the 'Physiologically safe (FDA) in respect of wetted materials' design comply with the following FDA guidelines:
Material | Guideline |
PTFE | 21CFR177.1510 |
PVDF | 21CFR177.2510 |
PP | 21CFR177.1520 |
EPDM/FKM | 21CFR177.2600 |
Dimensions of DHV-UR (FDA) (PP, PVC, PVDF design)
DN | G | H* | L | h | D | m | B |
---|---|---|---|---|---|---|---|
mm | mm | mm | mm | mm | |||
* Approximate values | |||||||
10 | 3/4 | 144 | 118 | 24 | 79 | M6 | 35 |
15 | 1 | 144 | 118 | 24 | 79 | M6 | 35 |
20 | 1 1/4 | 196 | 150 | 37 | 99 | M6 | 46 |
25 | 1 1/2 | 196 | 150 | 37 | 99 | M6 | 46 |
Dimensions of DHV-UR (FDA) (SS design)
DN | G | H* | L | h | D | m | B |
---|---|---|---|---|---|---|---|
mm | mm | mm | mm | mm | |||
* Approximate values | |||||||
10 | 3/4 | 144 | 118 | 24 | 79 | M6 | 35 |
15 | 1 | 144 | 118 | 24 | 79 | M6 | 35 |
20 | 1 1/4 | 196 | 150 | 37 | 99 | M6 | 46 |
25 | 1 1/2 | 196 | 150 | 37 | 99 | M6 | 46 |
We are happy to supply back pressure valves and relief valves DHV-U/DHV-UR in stainless steel and wetted EC 1935/2004 on request.
Relief valve type DHV-UR M configured for manometer
The relief valves DHV-UR with M designs are configured with a plug for manometer installation. Manometer with threaded socket G 1/4“ (ISO 228) can be fitted by the customer directly to the relief valve via the additional housing opening. Standard manometers with part number are available for neutral media. This also enables savings in terms of installation.
Adjustable pressure 0.5 - 10 bar
Application of PPE/PPB/PCE/PCB
20 °C - max. operating pressure 10 bar
Application of PVT/SST
30 °C - max. operating pressure 10 bar
Version | Nominal diameter | Dim. G | Order no. |
---|---|---|---|
PPE | DN 10 | 3/4 | 1077221 |
PPB | DN 10 | 3/4 | 1077259 |
PCE | DN 10 | 3/4 | 1077255 |
PVT | DN 10 | 3/4 | 1077267 |
PCB | DN 10 | 3/4 | 1077263 |
PPE | DN 15 | 1 | 1077220 |
PPB | DN 15 | 1 | 1077258 |
PCE | DN 15 | 1 | 1077254 |
PCB | DN 15 | 1 | 1077262 |
PVT | DN 15 | 1 | 1077266 |
PPE | DN 20 | 1 1/4 | 1077219 |
PCE | DN 20 | 1 1/4 | 1077223 |
PCB | DN 20 | 1 1/4 | 1077261 |
PVT | DN 20 | 1 1/4 | 1077265 |
PPB | DN 20 | 1 1/4 | 1077257 |
PPE | DN 25 | 1 1/2 | 1077218 |
PPB | DN 25 | 1 1/2 | 1077256 |
PCE | DN 25 | 1 1/2 | 1077222 |
PCB | DN 25 | 1 1/2 | 1077260 |
PVT | DN 25 | 1 1/2 | 1077264 |
Materials used
Version | Housing/Connectors | Plungers | Plunger Seal | Seal/Connectors |
---|---|---|---|---|
* Cover ring made from PTFE/FKM | ||||
PPE | PP | PVDF | EPDM | EPDM |
PPB | PP | PVDF | FKM | FKM |
PCE | PVC | PVDF | EPDM | EPDM |
PVT | PVDF | PVDF | PTFE * | FKM |
PCB | PVC | PVDF | FKM | FKM |
Dimensions of DHV-UR M (PP, PVC, PVDF design)
DN | G | H* | L | h | D | m | B |
---|---|---|---|---|---|---|---|
mm | mm | mm | mm | mm | |||
* Approximate values | |||||||
10 | 3/4 | 144 | 118 | 24 | 79 | M6 | 35 |
15 | 1 | 144 | 118 | 24 | 79 | M6 | 35 |
20 | 1 1/4 | 196 | 150 | 37 | 99 | M6 | 46 |
25 | 1 1/2 | 196 | 150 | 37 | 99 | M6 | 46 |
Back Pressure Valve / Relief Valve Type DHV 712-R
Adjustable pressure 0.5 - 10 bar
Application of PPE/PCB
20 °C - max. operating pressure 10 bar
Application of PVT/TT/SS
30 °C - max. operating pressure 10 bar
Version | Nominal diameter | Dim. G | Order no. |
---|---|---|---|
TT | DN 10 | 3/4 | 1000059 |
TT | DN 15 | 1 | 1000060 |
TT | DN 20 | 1 1/4 | 1000061 |
TT | DN 25 | 1 1/2 | 1000062 |
TT | DN 32 | 2 | 1000063 |
TT | DN 40 | 2 1/4 | 1000064 |
Caution: The product contains adhesive joints with Tangit. Please note the resistance of Tangit adhesive.
Dimensions of DHV 712-R
Dimension DN | Dim. G | Dim. H | Dim. L | Dimension h | Dim. D | Dimension m |
---|---|---|---|---|---|---|
DN | G | H | L | h | D | m |
10 | 3/4 | 173 | 120 | - | 81 | M6 |
15 | 1 | 173 | 120 | - | 81 | M6 |
20 | 1 1/4 | 201 | 150 | - | 107 | M6 |
25 | 1 1/2 | 201 | 150 | - | 107 | M6 |
32 | 2 | 260 | 205 | 59 / 37 | 147 | M8 |
40 | 2 1/4 | 260 | 205 | 59 / 37 | 147 | M8 |
Materials used
Version | Housing/Connectors | Plungers | Plunger Seal | Seal/Connectors |
---|---|---|---|---|
TT | Carbon-filled PTFE | PTFE | PTFE | PTFE |
Back Pressure Valve / Relief Valve for High-Pressure Systems
Material: stainless steel 316/FKM
Temperature range: -18 °C to 120 °C
Recommended use up to 200 l/h
Connector size | Order no. | |
---|---|---|
Overflow valve | 1/4" NPT inner and outer thread | 202505 |
Spring counter pressure min. | Spring counter pressure max. | Spring colour | Order no. |
---|---|---|---|
bar | bar | ||
3.4 | 24 | blue | 202519 |
24.0 | 52 | yellow | 202520 |
52.0 | 103 | violet | 202525 |
103.0 | 155 | orange | 202524 |
155.0 | 207 | brown | 202523 |
207.0 | 276 | white | 202522 |
276.0 | 345 | red | 202521 |
Recommended use up to 300 l/h
Connector size | Order no. | |
---|---|---|
Overflow valve | 1/2" NPT inner and outer thread | 1005499 |
Spring counter pressure min. | Spring counter pressure max. | Spring colour | Order no. |
---|---|---|---|
bar | bar | ||
3.4 | 24 | blue | 1005500 |
24.0 | 50 | yellow | 1005501 |
50.0 | 100 | violet | 1005502 |
Reducing pipe nipple
Connector size | Order no. |
---|---|
1/4" NPT internal – 1/4" NPT external (A) | 359378 |
1/4" NPT external – 1/4 Rp internal (B) | 359379 |
1/2" NPT internal – 1/2" NPT external (A) | 1005503 |
1/2" NPT external – 1/2 Rp internal (B) | 1005504 |
For use as an adjustable safety relief valve and as a back pressure valve. Relief valve and corresponding spring must be ordered separately
Downloads for Back Pressure Valves/Relief Valves for Motor-Driven Metering Pumps
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.
Overview
Accurately metered
Back pressure valves for motor-driven metering pumps are designed for different applications. Please refer to the relevant notes for the different designs.
Relief valves are used in the bypass to protect pumps, pipes and fittings from overpressure in the event of incorrect operation or blockages. In the event of a malfunction, the pump pumps back into the storage tank.
The benefits for you
- Protects against overpressure
- Priming aid
- Relieves the pressure line
- Increases dosing precision
Technical Data
Back Pressure Valve/Relief Valve Type DHV-U
Universal back pressure valves of the DHV-U product range are back pressure-free piston diaphragm valves with an internal flow. They are used to generate a constant back pressure and also as relief valves. They can be installed at any location in the pipework system.
Back pressure valves are used to generate a constant back pressure for precise pumping and to protect against over-metering where there is a free outlet, fluctuating back pressure or priming pressure on the suction side. They are also used in conjunction with pulsation dampers to generate low-pulsation metering.
Relief valves are used to protect pumps, pipes and fittings from overpressure, in the event of incorrect operation or blockages in the bypass. In the event of a malfunction, the pump pumps around the circuit or back into the supply tank.
Important: Back pressure valves cannot be used as absolutely leak-tight shut-off devices. Take appropriate safety precautions when handling hazardous media. Relief valves are not safety valves by their definition as per DIN EN ISO 4126-1.
Important: Take appropriate safety measures (e.g. flushing after possible response) when using as relief valves in conjunction with viscous media (e.g. lime milk).
Adjustable pressure 0.5 - 10 bar
Application of PPE/PPB/PCE/PCB
20 °C - max. operating pressure 10 bar
Application of PVT/SST
30 °C - max. operating pressure 10 bar
Version | Nominal diameter | Dim. G | Order no. |
---|---|---|---|
PPB | DN 10 | 3/4 | 1038133 |
PPE | DN 10 | 3/4 | 1037285 |
PCB Version | DN 10 | 3/4 | 1037765 |
PVT | DN 10 | 3/4 | 1037767 |
PCE | DN 10 | 3/4 | 1038144 |
SST | DN 10 | 3/4 | 1043194 |
PPB | DN 15 | 1 | 1038145 |
PPE | DN 15 | 1 | 1036816 |
PCB | DN 15 | 1 | 1037764 |
PVT | DN 15 | 1 | 1037766 |
PCE | DN 15 | 1 | 1038146 |
SST | DN 15 | 1 | 1043193 |
PPB | DN 20 | 1 1/4 | 1038147 |
PPE | DN 20 | 1 1/4 | 1037284 |
PCB | DN 20 | 1 1/4 | 1037775 |
PVT | DN 20 | 1 1/4 | 1037777 |
PCE | DN 20 | 1 1/4 | 1038148 |
SST | DN 20 | 1 1/4 | 1043192 |
PPB | DN 25 | 1 1/2 | 1038149 |
PPE | DN 25 | 1 1/2 | 1036633 |
PCB | DN 25 | 1 1/2 | 1037774 |
PVT | DN 25 | 1 1/2 | 1037776 |
PCE | DN 25 | 1 1/2 | 1038150 |
SST | DN 25 | 1 1/2 | 1043191 |
PPE | DN 32 | 2 | 1051517 |
PVT | DN 32 | 2 | 1051503 |
PCE | DN 32 | 2 | 1051514 |
SST | DN 32 | 2 | 1051516 |
PCB | DN 32 | 2 | 1051520 |
PPB | DN 32 | 2 | 1051522 |
PPE | DN 40 | 2 1/4 | 1051518 |
PCE | DN 40 | 2 1/4 | 1051501 |
PVT | DN 40 | 2 1/4 | 1051502 |
SST | DN 40 | 2 1/4 | 1051515 |
PCB | DN 40 | 2 1/4 | 1051519 |
PPB | DN 40 | 2 1/4 | 1051521 |
Materials used
Version | Housing/Connectors | Plungers | Plunger Seal | Seal/Connectors |
---|---|---|---|---|
* Cover ring made from PTFE/FKM | ||||
PPE | PP | PVDF | EPDM | EPDM |
PPB | PP | PVDF | FKM | FKM |
PCE | PVC | PVDF | EPDM | EPDM |
PCB | PVC | PVDF | FKM | FKM |
PVT | PVDF | PVDF | PTFE * | FKM |
SST | 1.4404 | PTFE | PTFE * | PTFE |
Dimensions of DHV-U (PP, PVC, PVDF design)
DN | G | H | L | h | D | m | B |
---|---|---|---|---|---|---|---|
mm | mm | mm | mm | mm | |||
10 | 3/4 | 144 | 118 | 24 | 79 | M6 | 40 |
15 | 1 | 144 | 118 | 24 | 79 | M6 | 40 |
20 | 1 1/4 | 196 | 150 | 37 | 99 | M6 | 46 |
25 | 1 1/2 | 196 | 150 | 37 | 99 | M6 | 46 |
32 | 2 | 252 | 200 | 54 | 139.5 | M8 | 65 |
40 | 2 1/4 | 252 | 200 | 54 | 139.5 | M8 | 65 |
Dimensions of DHV-U (SS version)
DN | G | H* | L | h | D | m | B |
---|---|---|---|---|---|---|---|
mm | mm | mm | mm | mm | |||
* Approximate values | |||||||
10 | 3/4 | 144 | 118 | 20 | 79 | M6 | 40 |
15 | 1 | 144 | 118 | 20 | 79 | M6 | 40 |
20 | 1 1/4 | 196 | 150 | 30 | 99 | M6 | 46 |
25 | 1 1/2 | 196 | 150 | 30 | 99 | M6 | 46 |
32 | 2 | 252 | 200 | 37 | 139.5 | M8 | 65 |
40 | 2 1/4 | 252 | 200 | 37 | 139.5 | M8 | 65 |
Back Pressure Valve/Relief Valve Type DHV-U in physiologically safe design (FDA)
Back pressure valves for motor-driven metering pumps are designed for different applications. Please refer to the relevant notes for the different designs.
Relief valves are used in the bypass to protect pumps, pipes and fittings from overpressure in the event of incorrect operation or blockages. In the event of a malfunction, the pump pumps back into the storage tank.
Adjustable pressure 0.5 - 10 bar
Application of PPE/PPB/PCE/PCB
20 °C - max. operating pressure 10 bar
Application of PVT/SST
30 °C - max. operating pressure 10 bar
Version | Nominal diameter | Dim. G | Order no. |
---|---|---|---|
PPE | DN 10 | 3/4 | 1076578 |
SST | DN 10 | 3/4 | 1076532 |
PVT | DN 10 | 3/4 | 1076579 |
PPE | DN 15 | 1 | 1076580 |
SST | DN 15 | 1 | 1076531 |
PVT | DN 15 | 1 | 1076581 |
PVT | DN 20 | 1 1/4 | 1076583 |
PPE | DN 20 | 1 1/4 | 1076582 |
SST | DN 20 | 1 1/4 | 1076597 |
PPE | DN 25 | 1 1/2 | 1076585 |
SST | DN 25 | 1 1/2 | 1076584 |
PVT | DN 25 | 1 1/2 | 1076586 |
PVT | DN 32 | 2 | 1076588 |
PPE | DN 32 | 2 | 1076587 |
SST | DN 32 | 2 | 1076589 |
PPE | DN 40 | 2 1/4 | 1076590 |
PVT | DN 40 | 2 1/4 | 1076591 |
SST | DN 40 | 2 1/4 | 1076592 |
Materials used
Version | Housing/Connectors | Plungers | Plunger Seal | Seal/Connectors |
---|---|---|---|---|
* Cover ring made from PTFE/FKM | ||||
PPE | PP | PVDF | EPDM | EPDM |
PVT | PVDF | PVDF | PTFE * | FKM |
SST | 1.4404 | PTFE | PTFE * | PTFE |
All wetted materials in the 'Physiologically safe (FDA) in respect of wetted materials' design comply with the following FDA guidelines:
Material | Guideline |
PTFE | 21CFR177.1510 |
PVDF | 21CFR177.2510 |
PP | 21CFR177.1520 |
EPDM/FKM | 21CFR177.2600 |
We are happy to supply back pressure valves and relief valves DHV-U/DHV-UR in stainless steel and wetted EC 1935/2004 on request.
Relief valve type DHV-UR
The universal relief valves type DHV-UR, like all valves of the DHV-U product range, are infinitely adjustable piston diaphragm valves with internal flow. In the event of impermissible overpressure, the internal piston diaphragm opens the second outlet line, the relief outlet. It can be installed at any location in the pipework system. Very low pressure losses with a closed relief valve due to virtually free pipe cross-section Simple spare parts management, the wear parts (pressure spring, diaphragms, plunger seal, seal connection set) correspond to the DHV-U range of valves.
The benefits of the new relief valves DHV-UR include simpler assembly due to the saving of installation material/connection parts etc. and a reduction of adhesion points. The new installation method permits a slimmer design of metering stations.
Relief valves for fitting directly into the discharge line of the motor-driven metering pump with the functions:
- Installation at any location in the pipework system.
- Very low pressure losses with a closed relief valve due to virtually free pipe cross-section
Adjustable pressure
0.5 – 10 bar
Application of PP and PVC (PPE/PPB/PCE/PCB)
20 °C - maximum operating pressure 10 bar
Application of PVDF and stainless steel (PVT/SST)
30 °C - maximum operating pressure 10 bar
The benefits for you:
- Simpler installation due to saving of installation material/connecting parts
- Reduced adhesion points.
- Slimmer construction type of metering stations.
- Simple spare parts management, wear parts conform to the DHV-U valve product range.
Version | Nominal diameter | Dim. G | Order no. |
---|---|---|---|
PVT | DN 10 | 3/4 | 1061365 |
PPE | DN 10 | 3/4 | 1061337 |
PCE | DN 10 | 3/4 | 1061339 |
PPB | DN 10 | 3/4 | 1061341 |
PCB | DN 10 | 3/4 | 1061343 |
SST | DN 10 | 3/4 | 1061550 |
PCB | DN 15 | 1 | 1061342 |
PPE | DN 15 | 1 | 1061336 |
PCE | DN 15 | 1 | 1061338 |
PPB | DN 15 | 1 | 1061340 |
PVT | DN 15 | 1 | 1061364 |
SST | DN 15 | 1 | 1061551 |
PCE | DN 20 | 1 1/4 | 1061369 |
PPE | DN 20 | 1 1/4 | 1061367 |
PPB | DN 20 | 1 1/4 | 1061371 |
PCB | DN 20 | 1 1/4 | 1061373 |
PVT | DN 20 | 1 1/4 | 1061375 |
SST | DN 20 | 1 1/4 | 1061569 |
PCE | DN 25 | 1 1/2 | 1061368 |
PPE | DN 25 | 1 1/2 | 1061366 |
PPB | DN 25 | 1 1/2 | 1061370 |
PCB | DN 25 | 1 1/2 | 1061372 |
PVT | DN 25 | 1 1/2 | 1061374 |
SST | DN 25 | 1 1/2 | 1061570 |
Materials used
Version | Housing/Connectors | Plungers | Plunger Seal | Seal/Connectors |
---|---|---|---|---|
* Cover ring made from PTFE/FKM | ||||
PPE | PP | PVDF | EPDM | EPDM |
PPB | PP | PVDF | FKM | FKM |
PCE | PVC | PVDF | EPDM | EPDM |
PCB | PVC | PVDF | FKM | FKM |
PVT | PVDF | PVDF | PTFE * | FKM |
SST | 1.4404 | 1.4404 | PTFE * | PTFE |
Dimensions of DHV-UR (PP, PVC, PVDF design)
DN | G | H* | L | h | D | m | B |
---|---|---|---|---|---|---|---|
mm | mm | mm | mm | mm | |||
* Approximate values | |||||||
10 | 3/4 | 144 | 118 | 24 | 79 | M6 | 35 |
15 | 1 | 144 | 118 | 24 | 79 | M6 | 35 |
20 | 1 1/4 | 196 | 150 | 37 | 99 | M6 | 46 |
25 | 1 1/2 | 196 | 150 | 37 | 99 | M6 | 46 |
Dimensions of DHV-UR (SS design)
DN | G | H* | L | h | D | m | B |
---|---|---|---|---|---|---|---|
mm | mm | mm | mm | mm | |||
* Approximate values | |||||||
10 | 3/4 | 144 | 118 | 24 | 79 | M6 | 35 |
15 | 1 | 144 | 118 | 24 | 79 | M6 | 35 |
20 | 1 1/4 | 196 | 150 | 37 | 99 | M6 | 46 |
25 | 1 1/2 | 196 | 150 | 37 | 99 | M6 | 46 |
Relief valve type DHV-UR, FDA design
Back pressure valves for motor-driven metering pumps are designed for different applications. Please refer to the relevant notes for the different designs.
Relief valves are used in the bypass to protect pumps, pipes and fittings from overpressure in the event of incorrect operation or blockages. In the event of a malfunction, the pump pumps back into the storage tank.
Adjustable pressure 0.5 - 10 bar
Application of PPE/PPB/PCE/PCB:
20 °C - max. operating pressure 10 bar
Application of PVT/SST:
30 °C - max. operating pressure 10 bar
Version | Nominal diameter | Dim. G | Order no. |
---|---|---|---|
PVT | DN 10 | 3/4 | 1075830 |
PPE | DN 10 | 3/4 | 1075828 |
SST | DN 10 | 3/4 | 1075847 |
PVT | DN 15 | 1 | 1075829 |
PPE | DN 15 | 1 | 1075827 |
SST | DN 15 | 1 | 1075846 |
PPE | DN 20 | 1 1/4 | 1075833 |
PVT | DN 20 | 1 1/4 | 1075845 |
SST | DN 20 | 1 1/4 | 1075849 |
PVT | DN 25 | 1 1/2 | 1075844 |
PPE | DN 25 | 1 1/2 | 1075832 |
SST | DN 25 | 1 1/2 | 1075848 |
Materials used
Version | Housing/Connectors | Plungers | Plunger Seal | Seal/Connectors |
---|---|---|---|---|
* Cover ring made from PTFE/FKM | ||||
PPE | PP | PVDF | EPDM | EPDM |
PVT | PVDF | PVDF | PTFE * | FKM |
SST | 1.4404 | PTFE | PTFE * | PTFE |
All wetted materials in the 'Physiologically safe (FDA) in respect of wetted materials' design comply with the following FDA guidelines:
Material | Guideline |
PTFE | 21CFR177.1510 |
PVDF | 21CFR177.2510 |
PP | 21CFR177.1520 |
EPDM/FKM | 21CFR177.2600 |
Dimensions of DHV-UR (FDA) (PP, PVC, PVDF design)
DN | G | H* | L | h | D | m | B |
---|---|---|---|---|---|---|---|
mm | mm | mm | mm | mm | |||
* Approximate values | |||||||
10 | 3/4 | 144 | 118 | 24 | 79 | M6 | 35 |
15 | 1 | 144 | 118 | 24 | 79 | M6 | 35 |
20 | 1 1/4 | 196 | 150 | 37 | 99 | M6 | 46 |
25 | 1 1/2 | 196 | 150 | 37 | 99 | M6 | 46 |
Dimensions of DHV-UR (FDA) (SS design)
DN | G | H* | L | h | D | m | B |
---|---|---|---|---|---|---|---|
mm | mm | mm | mm | mm | |||
* Approximate values | |||||||
10 | 3/4 | 144 | 118 | 24 | 79 | M6 | 35 |
15 | 1 | 144 | 118 | 24 | 79 | M6 | 35 |
20 | 1 1/4 | 196 | 150 | 37 | 99 | M6 | 46 |
25 | 1 1/2 | 196 | 150 | 37 | 99 | M6 | 46 |
We are happy to supply back pressure valves and relief valves DHV-U/DHV-UR in stainless steel and wetted EC 1935/2004 on request.
Relief valve type DHV-UR M configured for manometer
The relief valves DHV-UR with M designs are configured with a plug for manometer installation. Manometer with threaded socket G 1/4“ (ISO 228) can be fitted by the customer directly to the relief valve via the additional housing opening. Standard manometers with part number are available for neutral media. This also enables savings in terms of installation.
Adjustable pressure 0.5 - 10 bar
Application of PPE/PPB/PCE/PCB
20 °C - max. operating pressure 10 bar
Application of PVT/SST
30 °C - max. operating pressure 10 bar
Version | Nominal diameter | Dim. G | Order no. |
---|---|---|---|
PPE | DN 10 | 3/4 | 1077221 |
PPB | DN 10 | 3/4 | 1077259 |
PCE | DN 10 | 3/4 | 1077255 |
PVT | DN 10 | 3/4 | 1077267 |
PCB | DN 10 | 3/4 | 1077263 |
PPE | DN 15 | 1 | 1077220 |
PPB | DN 15 | 1 | 1077258 |
PCE | DN 15 | 1 | 1077254 |
PCB | DN 15 | 1 | 1077262 |
PVT | DN 15 | 1 | 1077266 |
PPE | DN 20 | 1 1/4 | 1077219 |
PCE | DN 20 | 1 1/4 | 1077223 |
PCB | DN 20 | 1 1/4 | 1077261 |
PVT | DN 20 | 1 1/4 | 1077265 |
PPB | DN 20 | 1 1/4 | 1077257 |
PPE | DN 25 | 1 1/2 | 1077218 |
PPB | DN 25 | 1 1/2 | 1077256 |
PCE | DN 25 | 1 1/2 | 1077222 |
PCB | DN 25 | 1 1/2 | 1077260 |
PVT | DN 25 | 1 1/2 | 1077264 |
Materials used
Version | Housing/Connectors | Plungers | Plunger Seal | Seal/Connectors |
---|---|---|---|---|
* Cover ring made from PTFE/FKM | ||||
PPE | PP | PVDF | EPDM | EPDM |
PPB | PP | PVDF | FKM | FKM |
PCE | PVC | PVDF | EPDM | EPDM |
PVT | PVDF | PVDF | PTFE * | FKM |
PCB | PVC | PVDF | FKM | FKM |
Dimensions of DHV-UR M (PP, PVC, PVDF design)
DN | G | H* | L | h | D | m | B |
---|---|---|---|---|---|---|---|
mm | mm | mm | mm | mm | |||
* Approximate values | |||||||
10 | 3/4 | 144 | 118 | 24 | 79 | M6 | 35 |
15 | 1 | 144 | 118 | 24 | 79 | M6 | 35 |
20 | 1 1/4 | 196 | 150 | 37 | 99 | M6 | 46 |
25 | 1 1/2 | 196 | 150 | 37 | 99 | M6 | 46 |
Back Pressure Valve / Relief Valve Type DHV 712-R
Adjustable pressure 0.5 - 10 bar
Application of PPE/PCB
20 °C - max. operating pressure 10 bar
Application of PVT/TT/SS
30 °C - max. operating pressure 10 bar
Version | Nominal diameter | Dim. G | Order no. |
---|---|---|---|
TT | DN 10 | 3/4 | 1000059 |
TT | DN 15 | 1 | 1000060 |
TT | DN 20 | 1 1/4 | 1000061 |
TT | DN 25 | 1 1/2 | 1000062 |
TT | DN 32 | 2 | 1000063 |
TT | DN 40 | 2 1/4 | 1000064 |
Caution: The product contains adhesive joints with Tangit. Please note the resistance of Tangit adhesive.
Dimensions of DHV 712-R
Dimension DN | Dim. G | Dim. H | Dim. L | Dimension h | Dim. D | Dimension m |
---|---|---|---|---|---|---|
DN | G | H | L | h | D | m |
10 | 3/4 | 173 | 120 | - | 81 | M6 |
15 | 1 | 173 | 120 | - | 81 | M6 |
20 | 1 1/4 | 201 | 150 | - | 107 | M6 |
25 | 1 1/2 | 201 | 150 | - | 107 | M6 |
32 | 2 | 260 | 205 | 59 / 37 | 147 | M8 |
40 | 2 1/4 | 260 | 205 | 59 / 37 | 147 | M8 |
Materials used
Version | Housing/Connectors | Plungers | Plunger Seal | Seal/Connectors |
---|---|---|---|---|
TT | Carbon-filled PTFE | PTFE | PTFE | PTFE |
Back Pressure Valve / Relief Valve for High-Pressure Systems
Material: stainless steel 316/FKM
Temperature range: -18 °C to 120 °C
Recommended use up to 200 l/h
Connector size | Order no. | |
---|---|---|
Overflow valve | 1/4" NPT inner and outer thread | 202505 |
Spring counter pressure min. | Spring counter pressure max. | Spring colour | Order no. |
---|---|---|---|
bar | bar | ||
3.4 | 24 | blue | 202519 |
24.0 | 52 | yellow | 202520 |
52.0 | 103 | violet | 202525 |
103.0 | 155 | orange | 202524 |
155.0 | 207 | brown | 202523 |
207.0 | 276 | white | 202522 |
276.0 | 345 | red | 202521 |
Recommended use up to 300 l/h
Connector size | Order no. | |
---|---|---|
Overflow valve | 1/2" NPT inner and outer thread | 1005499 |
Spring counter pressure min. | Spring counter pressure max. | Spring colour | Order no. |
---|---|---|---|
bar | bar | ||
3.4 | 24 | blue | 1005500 |
24.0 | 50 | yellow | 1005501 |
50.0 | 100 | violet | 1005502 |
Reducing pipe nipple
Connector size | Order no. |
---|---|
1/4" NPT internal – 1/4" NPT external (A) | 359378 |
1/4" NPT external – 1/4 Rp internal (B) | 359379 |
1/2" NPT internal – 1/2" NPT external (A) | 1005503 |
1/2" NPT external – 1/2 Rp internal (B) | 1005504 |
For use as an adjustable safety relief valve and as a back pressure valve. Relief valve and corresponding spring must be ordered separately
Downloads
Downloads for Back Pressure Valves/Relief Valves for Motor-Driven Metering Pumps
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.
Contact us
Mr. Vikalp Tripathi
Managing Director, Heidelberg ProMinent Fluid Controls India Pvt. Ltd.