Bypass Fittings for Sensors
Your sensors are ideally accommodated in the bypass fitting. This fitting ensures optimum measuring conditions.
Product description
In-flow measurement
We offer a range of bypass fittings for specific integration into processes. They hold potentiometric and amperometric sensors as well as conductivity sensors and ensure optimum operating conditions for measurement.
Sensor bypass armature Modular BAMa
Your Benefits
- The sensors can be quickly and easily fitted and dismantled thanks to bayonet fittings.
- All parts requiring maintenance can be cleaned very well as they are easy to access without tools.
- Water consumption is minimised to just 5 l/h for flow-dependent sensors under ideal measurement conditions.
- The good particle mobility allows the bypass armature to be used in an even wider range of applications.
- Construction and material permit temperatures of up to 70 °C at a max. pressure of 3 bar, making it even more flexible to use.
- Thanks to higher pressure levels of up to 7 bar at 20 °C, sample water can return to the process, where permitted.
- The BAMa provides numerous options for setting optimum measurement conditions.
Technical Data
Application | Drinking water or similar with sample water drained | Water from Pool & Wellness or similar with sample water returned to process | Industrial water or similar with a solids content and higher temperature and pressure requirements |
Flow through the BAMa fiiting | 5…25 l/h | 20…60 l/h | 20…100 l/h |
Minimum priming pressure without flow limiter and with clean filter, for a total of 9 modules | 0.025 bar | 0.05 bar | 0.5 bar |
Minimum priming pressure with flow limiter and with clean filter, for a total of 9 modules | 1.5 bar | 1.5 bar | 2.0 bar |
Maximum operating pressure | 7.0 bar at 20 °C | 7.0 bar at 20 °C | 7.0 bar at 20 °C |
Maximum operating temperature | 60 °C at 3.5 bar | 60 °C at 3.5 bar | 70 °C at 3.0 bar |
Surrounding temperature | -10…60°C | -10…60°C | -10…60°C |
Particle mobility (proved with non-agglomerating, non-sedimentary model particles) | < 300 µm | < 300 µm | < 1,000 µm |
Bypass fitting type DLG III
To hold 2 sensors (conductivity, Pt 100, pH or ORP sensors) with PG 13.5 screw-in thread plus one sensor with R 1" screw-in thread (amperometric sensors) with integrated stainless steel pin as liquid reference potential.
On the inlet side, the DLG III is equipped with a plastic ball valve for blocking and adjusting the sample water flow.
Material | In-line probe housing: PVC hard |
Max. pressure | 1.0 bar |
Max. temperature | 55 °C |
Typical applications | Cooling water, slightly contaminated wastewater, turbid water, no sludge. |
Version | Max. temperature | Order no. | |
---|---|---|---|
°C | |||
DLG III A with PVC hose connectors | for PE line Ø 8/5 mm | 55 | 914955 |
DLG III A with flushing connector and PVC hose connection | for PE line Ø 8/5 mm | 55 | 1029096 |
DLG III B with PVC adhesive connectors | for pipe connection Ø 16 DN 10 | 55 | 914956 |
Assembly kit for fitting amperometric sensors | 55 | 815079 |
DLG Sampling Water Cup
Order no. | |
---|---|
DLG III sampling water cup with back flush device | 1029095 |
DLG IV Type In-Line Probe Housing
To hold 4 sensors (pH, ORP, Pt 100, conductivity) with PG 13.5 screw-in thread. With integrated stainless steel rod as liquid reference potential. Angle for wall mounting.
Material | In-line probe housing: PVC hard or PP Clear cup: Polyamide |
Max. pressure | 1.0 bar |
Connection for sample water line | Union with d 16/DN 10 insert |
Version | Max. temperature | Order no. | |
---|---|---|---|
°C | |||
DLG IV PP | for Ø 16/DN 10 pipe work connector | 80 | 1005331 |
DLG IV PVC | for Ø 16/DN 10 pipe work connector | 55 | 1005332 |
Downloads for Bypass Fittings for Sensors
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.
Overview
In-flow measurement
We offer a range of bypass fittings for specific integration into processes. They hold potentiometric and amperometric sensors as well as conductivity sensors and ensure optimum operating conditions for measurement.
Technical Data
Sensor bypass armature Modular BAMa
Your Benefits
- The sensors can be quickly and easily fitted and dismantled thanks to bayonet fittings.
- All parts requiring maintenance can be cleaned very well as they are easy to access without tools.
- Water consumption is minimised to just 5 l/h for flow-dependent sensors under ideal measurement conditions.
- The good particle mobility allows the bypass armature to be used in an even wider range of applications.
- Construction and material permit temperatures of up to 70 °C at a max. pressure of 3 bar, making it even more flexible to use.
- Thanks to higher pressure levels of up to 7 bar at 20 °C, sample water can return to the process, where permitted.
- The BAMa provides numerous options for setting optimum measurement conditions.
Technical Data
Application | Drinking water or similar with sample water drained | Water from Pool & Wellness or similar with sample water returned to process | Industrial water or similar with a solids content and higher temperature and pressure requirements |
Flow through the BAMa fiiting | 5…25 l/h | 20…60 l/h | 20…100 l/h |
Minimum priming pressure without flow limiter and with clean filter, for a total of 9 modules | 0.025 bar | 0.05 bar | 0.5 bar |
Minimum priming pressure with flow limiter and with clean filter, for a total of 9 modules | 1.5 bar | 1.5 bar | 2.0 bar |
Maximum operating pressure | 7.0 bar at 20 °C | 7.0 bar at 20 °C | 7.0 bar at 20 °C |
Maximum operating temperature | 60 °C at 3.5 bar | 60 °C at 3.5 bar | 70 °C at 3.0 bar |
Surrounding temperature | -10…60°C | -10…60°C | -10…60°C |
Particle mobility (proved with non-agglomerating, non-sedimentary model particles) | < 300 µm | < 300 µm | < 1,000 µm |
Bypass fitting type DLG III
To hold 2 sensors (conductivity, Pt 100, pH or ORP sensors) with PG 13.5 screw-in thread plus one sensor with R 1" screw-in thread (amperometric sensors) with integrated stainless steel pin as liquid reference potential.
On the inlet side, the DLG III is equipped with a plastic ball valve for blocking and adjusting the sample water flow.
Material | In-line probe housing: PVC hard |
Max. pressure | 1.0 bar |
Max. temperature | 55 °C |
Typical applications | Cooling water, slightly contaminated wastewater, turbid water, no sludge. |
Version | Max. temperature | Order no. | |
---|---|---|---|
°C | |||
DLG III A with PVC hose connectors | for PE line Ø 8/5 mm | 55 | 914955 |
DLG III A with flushing connector and PVC hose connection | for PE line Ø 8/5 mm | 55 | 1029096 |
DLG III B with PVC adhesive connectors | for pipe connection Ø 16 DN 10 | 55 | 914956 |
Assembly kit for fitting amperometric sensors | 55 | 815079 |
DLG Sampling Water Cup
Order no. | |
---|---|
DLG III sampling water cup with back flush device | 1029095 |
DLG IV Type In-Line Probe Housing
To hold 4 sensors (pH, ORP, Pt 100, conductivity) with PG 13.5 screw-in thread. With integrated stainless steel rod as liquid reference potential. Angle for wall mounting.
Material | In-line probe housing: PVC hard or PP Clear cup: Polyamide |
Max. pressure | 1.0 bar |
Connection for sample water line | Union with d 16/DN 10 insert |
Version | Max. temperature | Order no. | |
---|---|---|---|
°C | |||
DLG IV PP | for Ø 16/DN 10 pipe work connector | 80 | 1005331 |
DLG IV PVC | for Ø 16/DN 10 pipe work connector | 55 | 1005332 |
Downloads
Downloads for Bypass Fittings for Sensors
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.
Contact us
Mr. Vikalp Tripathi